Ultrasound use in shock

Is ultrasound useful in shock? Jo McDonnell

Aim  Highlight what you could have a go at…  Highlight what the sonoboys could do for you to help assess your patient

Shock Clinical situation where there is hypoperfusion of the cells and tissues

Background  Patients with shock have high mortality rates and these rates are correlated to the amount and duration of hypotension.  Diagnosis and initial care must be accurate and prompt to optimise patient outcomes.  Studies have demonstrated that initial integration of bedside ultrasound into the evaluation of the patient with shock results in a more accurate initial diagnosis with earlier definitive treatment.  Bedside USS allows direct visualisation of pathology or abnormal physiological states.

Remember…  Ultrasound is a tool to aid diagnosis, but it won’t tell you everything…  When using it we should always have a clinical question you would like it to answer

Case 1:  75 yo male, unwell, chest pain, SOB, dirty productive cough  Lung cancer, angina and CCF  pyrexic at 38.2  HR 110  BP 80/50  Swollen pitting oedema bilaterally

Case 1- What clinical question can the probe answer for you with this patient?

RUSH  Rapid ultrasound in shock and hypotension- US protocol published with aim to differentiate classification of shock  Perera P et al, Emerg Med Clin N Am 2010  H eart  I vc  M orrisons pouch/FAST  A orta  P neumothorax

Himap-THE PUMP  Contractility- Hyperdynamic LV- sepsis, hypovolaemia  Hypodynamic- late sepsis, cardiogenic shock  What’s the RV like? – collapsing? Dilated?   Obstructive shock  Gross valvular dysfunction

Cardiac assessment

Parasternal long axis  Transducer at left sternal edge between 2nd -4th intercostal space  Probe marker pointing to patients R shoulder  Probe aligned along the long axis: from R shoulder to cardiac apex.  Useful view to assess contractility

 Transducer at 4th-6th intercostal space in the midclavicular to anterior-axillary line.  Probe directed towards patient’s right shoulder with the marker directed towards the left shoulder.  Important view to give relative dimensions of L and R ventricle.  Normal ventricular diameter ratio of R ventricle to L ventricle is <0.7.

Pericardial Tamponade  Remember tamponade is a clinical diagnosis based on patient’s haemodynamics and clinical picture.  Ultrasound may demonstrate early warning signs of tamponade before the patient becomes haemodynamically unstable.  Haemodynamic effects  Its PRESSURE NOT SIZE THAT COUNTS!  Rate of formation affects pressure-volume relationship and is therefore more important than volume of fluid.

Tamponade using ultrasound  A moderate-large effusion.  Right atrial collapse  Atrial contraction normal in atrial systole  Collapse throughout diastole or inversion is abnormal.  RV collapse during diastole when meant to be filling (‘scalloping’ seen)  Whats seen in the IVC…

I h map  IVC

Where to put the probe…  Probe position Subxiphoid  Orientate probe in longitudinal plane with probe indicator to patient’s head  Slightly to right of midline 

Bowel gas causing problems….

The FAST view…  Probe goes longitudinally in right mid axillary line with marker towards head.  Look for IVC running longitudinally adjacent to the liver crossing the diaphragm  Track superiorly until it enters the RA confirms it’s the IVC not the aorta

Assessing the IVC  During inspiration, intrathoracic pressure becomes more negative, abdominal pressure becomes more positive, resultant increase in the pressure gradient between the supra and infra-diaphragmatic vena cava, increases venous return to the heart.  Given the extrathoracic IVC is a very compliant vessel this causes diameter of IVC to decrease with normal inspiration.  In patients with low intravascular volume, the inspiration to expiration diameters change much more than those who have normal or high intravascular volume.

Estimating the CVP Right atrial pressures, representing central venous pressure, can be estimated by viewing the respiratory change in the diameter of the IVC.

American society of Echocardiography 2010 guidelines

Subxiphoid long; shocked and dry

Subxiphoid transverse view of the IVC and aorta

Complicating the picture  Valvular disease  Pulmonary hypertension  Increased intraabdominal pressure

hiMAp eFAST/Aorta scan

himaP  Multiple studies have shown ultrasound to be more sensitive than supine CXR for the detection of pneumothorax.  Sensitivities ranged from 86-100% with specificities from 92-100%.  Furthermore USS can be performed more rapidly at the bedside.  Detection with ultrasound relies on the fact that free air is lighter than normal aerated lung tissue, and thus will accumulate in the nondependent areas of the thoracic cavity. (ie anteriorly when patient is supine).

To get the lung window  Patient should be supine.  Use high frequency linear array or a phased array transducer.  Position in the midclavicular line, 3rd to 4th intercostal space with probe oriented longitudinally.  Position between ribs.


Abdominal and cardiac evaluation with sonography in the hypotensive patient (ACES)

Our case…  H- no pericardial effusion  I- 1cm and collapses >50%  M- Free fluid in the LUQ/RUQ  Aorta- no AAA  P – No pneumothorax

Next time…Give the probe a go…

Add a comment

Related presentations

Related pages

Bedside Ultrasound in Resuscitation and the Rapid ...

Assessment of hemodynamic status in a shock state remains a challenging issue in Emergency Medicine and Critical Care. As the use of invasive ...
Read more

The RUSH Exam - Rapid Ultrasound for Shock and Hypotension

The RUSH Exam: Rapid Ultrasound for Shock and Hypotension. Scott D. Weingart, MD RDMS, Daniel Duque MD RDMS, Bret Nelson MD RDMS. Hear the Lecture
Read more

ultrasound use in shock

A presentation highlighting the usefulness of US in the assessment and management of a patient with shock. Ultrasound can be used as an extension of your ...
Read more

How do shock waves differ from ultrasound? | Focus-It

Shock waves have different characteristics in comparison to ultrasound. Ultrasound usually consists of periodic oscillations with limited bandwidth.
Read more

Review Article - EMCrit Blog - Emergency Department ...

far field of the ultrasound image with use of a low-frequency probe. (C) Compromise of the Tank: ... exam: rapid Ultrasound in SHock in the evaluation of the
Read more

Abdominal and Cardiothoracic Evaluation with Sonography in ...

... The Abdominal and Cardiac Evaluation with Sonography in Shock (ACES) protocol: ultrasound ... The use of ultrasound-guided IVC assessment for ...
Read more

Bedside ultrasound in resuscitation and the rapid ...

Bedside ultrasound in resuscitation and the rapid ultrasound in shock protocol. Seif D, Perera P, ... As the use of invasive hemodynamic monitoring ...
Read more

Rapid Ultrasound in Shock - Family Practice Notebook

This page includes the following topics and synonyms: Rapid Ultrasound in Shock, RUSH Exam.
Read more