s7 400 cpu

6 © Siemens AG 2011 SIMATIC S7-400 6/2 Introduction 6/4 6/4 6/4 6/17 6/32 6/47 6/52 6/54 6/54 6/62 6/75 6/75 6/75 6/75 6/84 6/92 6/93 6/93 6/94 Central processing units Standard CPUs CPU 412 CPU 414 CPU 416 CPU 417 SIPLUS Standard CPUs Fail-safe CPUs CPU 414F CPU 416F Fault-tolerant CPUs CPU 412H CPU 414H CPU 417H Sync-module for coupling the CPU 41xH Y-Link for S7-400H SIPLUS fault-tolerant CPUs SIPLUS sync module for connecting the CPU 41xH SIPLUS Y-Link for S7-400H Interface modules IF-964 DP PROFIBUS module SIPLUS IF-964 DP interface module 6/146 6/148 6/150 6/153 Ch. 5 Ch. 5 Communication CP 440 CP 441-1, CP 441-2 Loadable drivers for CP 441-2 and CP 341 CP 443-5 Basic CP 443-5 Extended CP 443-1 CP 443-1 Advanced TIM 4R-IE for WAN and Ethernet TIM 4R-IE DNP3 6/158 SIPLUS communication 6/162 6/162 6/163 Connection methods Front connectors SIMATIC TOP connect for SIMATIC S7 6/172 6/172 6/174 6/175 Racks Racks Fan subassembly Expansion devices 6/176 SIPLUS module racks 6/177 6/177 6/178 6/179 6/180 6/181 6/182 6/183 Interface modules IM 460-0 IM 461-0 IM 460-1 IM 461-1 IM 460-3 IM 461-3 IM 463-2 6/95 6/95 6/98 Digital modules SM 421 digital input module SM 422 digital output module 6/101 SIPLUS digital modules 6/103 6/103 6/112 Analog modules SM 431 analog input module SM 432 analog output module 6/184 SIPLUS interface modules 6/186 Power supplies 6/114 SIPLUS analog modules 6/116 6/116 6/118 6/120 6/122 6/124 6/128 Function modules FM 450-1 counter module FM 451 positioning module FM 452 cam controller FM 453 positioning module FM 455 controller module FM 458-1 DP application module 6/190 6/190 6/191 Accessories Labeling sheets Spare parts 6/192 6/192 6/196 6/198 6/199 6/200 Modules for SIMATIC S7-400F/FH IM 153-1/153-2 SIPLUS IM 153-6/153-2 Isolation module SIPLUS isolation module Fail-safe input/output modules 6/139 SIPLUS function modules 6/85 6/88 6/91 6/141 6/141 6/142 6/144 Brochures For brochures serving as selection guides for SIMATIC products refer to: http://www.siemens.com/simatic/ printmaterial Siemens ST 70 · 2011

© Siemens AG 2011 SIMATIC S7-400 Introduction S7-400/S7-400H/S7-400F/FH ■ Overview The S7-400 is the most powerful PLC in the family of SIMATIC controllers. It enables successful automation solutions with Totally Integrated Automation (TIA). The S7-400 is an automation platform for system solutions in production and process engineering, and it is characterized primarily by its modularity and performance reserves. 6 S7-400 • The power PLC for the mid to high-end performance ranges. • The solution for even the most demanding tasks. • With a comprehensive range of modules and performancegraded CPUs for optimal adaptation to the automation task. • Flexible in use through simple implementation of distributed structures; user-friendly connections. • Optimal communication and networking options. • User-friendly handling and uncomplicated design without a fan. • Can be expanded without problems when the tasks increase. • Multicomputing: Simultaneous operation of several CPUs in one S7-400 central controller. Multicomputing distributes the overall performance power of an S7-400. For example, complex tasks can be divided into technologies such as open-loop control, computing or communication, and assigned to different CPUs. And every CPU can be assigned its own local I/O. • Modularity: The powerful backplane bus of the S7-400 and the communication interfaces that can be connected direct to the CPU enable high-performance operation of a host of communication lines. This enables, for example, division into one communication path for HMI and programming tasks, one for high-performance and equidistant motion control components, and one for a "normal" I/O fieldbus. Additionally required connections to MES/ERP systems or the Internet can also be implemented. • Engineering and diagnostics: The S7-400 is configured and programmed extremely efficiently together with the SIMATIC Engineering Tools particularly in the case of extensive automation solutions with a high engineering component. For this purpose, high-level languages such as SCL and graphical engineering tools for sequential controls, state graph programs and technology-oriented diagrams are available, for example. 6/2 Siemens ST 70 · 2011 S7-400H • Fault-tolerant automation system with redundant design. • For applications with high fail-safety requirements. Processes with high restart costs, expensive downtimes, little supervision, and few maintenance options. • Redundant central functions. • Increases availability of I/O: switched I/O configuration. • Also possible to use I/Os with standard availability: singlesided configuration. • Hot stand-by: automatic reaction-free switching to the standby unit in the event of a fault. • Configuration with two separate or one divided central rack. • Connection of switched I/O via redundant PROFIBUS DP.

© Siemens AG 2011 SIMATIC S7-400 Introduction S7-400/S7-400H/S7-400F/FH ■ Overview (continued) ■ Technical specifications General technical specifications Degree of protection IP20 Ambient temperature 0 to 60 °C Relative humidity 5 to 95%, no condensation Atmospheric pressure 1080 to 795 hPa (corresponds to an altitude of 1000 m to 2000 m) Electromagnetic compatibility • Interference immunity • Emitted interference Mechanical load • Vibration, test according to / tested with S7-400F/FH • Failsafe automation system for plants with increased safety requirements • Complies with safety requirements to SIL 3 in accordance with IEC 61508, AK6 in accordance with DIN V 19250 and Cat. 4 in accordance with EN 954-1 • If required, also fault tolerant through redundant design • Without additional wiring of the safety-related I/O: • Safety-relevant communication via PROFIBUS DP with PROFIsafe profile • Based on S7-400H and ET 200M with fail-safe modules • Standard modules for non-safety-related applications can also be used in the automation system • Isolation module for joint use of fail-safe and standard modules in safety mode in one ET 200M • Shock, test according to / tested with According to EN 61000-6-2 According to EN 61000-6-4 IEC 60068-2-6 (sine) 10 to 58 Hz; constant amplitude 0.075 mm; 58 to 500 Hz; constant acceleration 1 g; duration of oscillation: 10 frequency sweeps per axis in each direction of the three mutually perpendicular axes IEC 60068-2-27 Type of shock: Half-sine; strength of the shock 10 g (peak value), duration 6 ms direction of shock: 100 shocks in each of the 3 mutually perpendicular axes. For brochures serving as selection guides for SIMATIC products refer to: www.siemens.com/simatic/printmaterial Siemens ST 70 · 2011 6/3 6

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 412 ■ Overview • The low-cost starter solution for the medium performance range • Can be used in small and medium-sized systems with requirements of the medium performance range 6 ■ Technical specifications 6ES7 412-1XJ05-0AB0 6ES7 412-2XJ05-0AB0 6ES7 412-2EK06-0AB0 Product type designation CPU 412-1 CPU 412-2 CPU 412-2 PN Product version Hardware product version 03 03 01 Firmware version V5.3 V5.3 V6.0 Associated programming package STEP7 V 5.3 SP2 or higher with HW update STEP7 V 5.3 SP2 or higher with HW update STEP7 V5.5 or higher/iMap V3.0 + iMap STEP7 Add-on V3.0 SP5 or higher No; Power supply via system power supply No; Power supply via system power supply No; Power supply via system power supply 5 to 15 V DC 5 to 15 V DC 5 to 15 V DC Current consumption from backplane bus 5 V DC, max. 0.6 A 1.1 A 1.3 A from interface 5 V DC, max. 90 mA 90 mA; At each DP interface 90 mA; At the DP interface Power losses Power loss, typ. 2.5 W 4.5 W 5.5 W Power loss, max. 3W 5W 6.5 W Backup battery Battery operation • Backup current, typ. • Backup current, max. not relevant 125 μA; (up to 40 °C) 300 μA not relevant 125 μA; (up to 40 °C) 550 μA not relevant 125 μA; (up to 40 °C) 450 μA Memory Work memory • integrated (for program) • integrated (for data) • expandable 144 Kibyte 144 Kibyte No 256 Kibyte 256 Kibyte No 0.5 Mbyte 0.5 Mbyte No Load memory • expandable FEPROM • expandable FEPROM, max. • integrated RAM, max. • expandable RAM • expandable RAM, max. Yes; with Memory Card (FLASH) 64 Mbyte 512 Kibyte Yes; with Memory Card (RAM) 64 Mbyte Yes; with Memory Card (FLASH) 64 Mbyte 512 Kibyte Yes; with Memory Card (RAM) 64 Mbyte Yes; with Memory Card (FLASH) 64 Mbyte 512 Kibyte Yes; with Memory Card (RAM) 64 Mbyte Backup • present • with battery • without battery Yes Yes; All data No Yes Yes; All data No Yes Yes; All data No Supply voltages Rated value • 24 V DC Feeding of external backup voltage to CPU 6/4 Siemens ST 70 · 2011

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 412 ■ Technical specifications (continued) 6ES7 412-1XJ05-0AB0 6ES7 412-2XJ05-0AB0 6ES7 412-2EK06-0AB0 CPU-blocks DB • Number, max. • Size, max. 1 500; Number range: 1 to 16,000 64 Kibyte 3 000; Number range: 1 to 16,000 64 Kibyte 3 000; Number range: 1 to 16,000 64 Kibyte FB • Number, max. • Size, max. 750; Number range: 0 to 7999 64 Kibyte 1 500; Number range: 0 to 7999 64 Kibyte 1 500; Number range: 0 to 7999 64 Kibyte FC • Number, max. • Size, max. 750; Number range: 0 to 7999 64 Kibyte 1 500; Number range: 0 to 7999 64 Kibyte 1 500; Number range: 0 to 7999 64 Kibyte OB • Size, max. 64 Kibyte 64 Kibyte 64 Kibyte Nesting depth • per priority class • additional within an error OB 24 1 24 1 24 1 CPU processing times for bit operations, min. 75 ns 75 ns 75 ns for word operations, min. 75 ns 75 ns 75 ns for fixed point arithmetic, min. 75 ns 75 ns 75 ns for floating point arithmetic, min. 225 ns 225 ns 225 ns 2 048 2 048 2 048 Yes 0 2 047 Z 0 to Z 7 Yes 0 2 047 Z 0 to Z 7 Yes 0 2 047 Z 0 to Z 7 0 999 0 999 0 999 Yes SFB Unlimited (limited only by work memory) Yes SFB Unlimited (limited only by work memory) Yes SFB Unlimited (limited only by work memory) 2 048 2 048 2 048 Yes 0 2 047 No times retentive Yes 0 2 047 No times retentive Yes 0 2 047 No times retentive 10 ms 9 990 s 10 ms 9 990 s 10 ms 9 990 s Yes SFB Unlimited (limited only by work memory) Yes SFB Unlimited (limited only by work memory) Yes SFB Unlimited (limited only by work memory) Counters, timers and their retentivity S7 counter • Number • Retentivity - adjustable - lower limit - upper limit - preset • Counting range - lower limit - upper limit IEC counter • present • Type • Number S7 times • Number • Retentivity - adjustable - lower limit - upper limit - preset • Time range - lower limit - upper limit IEC timer • present • Type • Number Siemens ST 70 · 2011 6 6/5

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 412 ■ Technical specifications (continued) 6ES7 412-1XJ05-0AB0 6ES7 412-2XJ05-0AB0 6ES7 412-2EK06-0AB0 Total working and load memory (with backup battery) Total working and load memory (with backup battery) Total working and load memory (with backup battery) • Retentivity available • Number of clock memories 4 Kibyte; Size of bit memory address area Yes 8; (in 1 memory byte) 4 Kibyte; Size of bit memory address area Yes 8; (in 1 memory byte) 4 Kibyte; Size of bit memory address area Yes 8; (in 1 memory byte) Data blocks • Number, max. • Size, max. 1 500; Number range: 1 to 16,000 64 Kibyte 3 000; Number range: 1 to 16,000 64 Kibyte 3 000; Number range: 1 to 16,000 64 Kibyte Local data • adjustable, max. • preset 8 Kibyte 4 Kibyte 8 Kibyte 4 Kibyte 8 Kibyte 4 Kibyte 4 Kibyte 4 Kibyte 4 Kibyte 4 Kibyte 4 Kibyte 4 Kibyte 2 Kibyte 2 Kibyte 2 Kibyte 2 Kibyte 4 Kibyte 4 Kibyte 2 Kibyte 2 Kibyte Data areas and their retentivity retentive data area, total Flag • Number, max. 6 Address area I/O address area • overall • Outputs • of which, distributed - MPI/DP interface, inputs - MPI/DP interface, outputs - DP interface, inputs - DP interface, outputs - PN interface, inputs - PN interface, outputs 4 Kibyte 4 Kibyte Process image • Inputs, adjustable • Outputs, adjustable • Inputs, preset • Outputs, preset • Consistent data, max. • Access to consistent data in process image 4 Kibyte 4 Kibyte 128 byte 128 byte 244 byte Yes 4 Kibyte 4 Kibyte 128 byte 128 byte 244 byte Yes 4 Kibyte 4 Kibyte 128 kbyte 128 Kibyte 244 byte Yes Subprocess images • Number of subprocess images, max. 15 15 15 Digital channels • Inputs • Outputs • Inputs, of which central • Outputs, of which central 32 768 32 768 32 768 32 768 32 768 32 768 32 768 32 768 32 768 32 768 32 768 32 768 Analog channels • Inputs • Outputs • Inputs, of which central • Outputs, of which central 2 048 2 048 2 048 2 048 2 048 2 048 2 048 2 048 2 048 2 048 2 048 2 048 6/6 Siemens ST 70 · 2011

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 412 ■ Technical specifications (continued) 6ES7 412-1XJ05-0AB0 6ES7 412-2XJ05-0AB0 6ES7 412-2EK06-0AB0 Hardware configuration connectable OPs 31 31 47 Central devices, max. 1 1 1 Expansion devices, max. 21 21 21 Multicomputing Yes; 4 CPUs max. (with UR1 or UR2) Yes; 4 CPUs max. (with UR1 or UR2) Yes; 4 CPUs max. (with UR1 or UR2) 6 6 6 6 6 6 4; IM 463-2 4; IM 463-2 4; IM 463-2 1 4 10; CP 443-5 Extended No; IM 467 not suitable for use with CP 443-5 Ext. and CP443-1 EX4x, EX20, GX20 (in PNIO mode) 0 6 2 4 10; CP 443-5 Extended No; IM 467 not suitable for use with CP 443-5 Ext. and CP443-1 EX4x, EX20, GX20 (in PNIO mode) 0 6 1 4 10; CP 443-5 Extended No; IM 467 not suitable for use with CP 443-5 Ext. and CP443-1 EX4x, EX20, GX20 (in PNIO mode) 0 6 0 4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller 0 4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller 1 4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller Limited by number of slots and number of connections CP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections 14; Of which 10 CPs max. or IMs as DP master, 4 PN controller maximum Limited by number of slots and number of connections CP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections 14; Of which 10 CPs max. or IMs as DP master, 4 PN controller maximum Limited by number of slots and number of connections CP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections 14; In total max. 10 CPs as DP master and PN controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PN controller Time Clock • Hardware clock (real-time clock) Yes • battery-backed and synchronizable Yes • Resolution 1 ms Yes Yes 1 ms Yes Yes 1 ms Runtime meter • Number 16 16 16 Clock synchronization • supported • to MPI, master • to MPI, slave • to DP, master • to DP, slave • in AS, master • in AS, slave • on Ethernet via NTP • to IF 964 DP Yes Yes Yes Yes Yes Yes Yes No; Via CP No Yes Yes Yes Yes Yes Yes Yes No; Via CP No Yes Yes Yes Yes Yes Yes Yes Yes; as client Interface modules • Number of connectable IMs (total), max. • Number of connectable IM 460s, max. • Number of connectable IM 463s, max. Number of DP masters • integrated • via IM 467 • via CP • Mixed mode IM + CP permitted • via interface module • Number of pluggable S5 modules (via adapter capsule in central device), max. Number of IO controllers • integrated • via CP Number of operable FMs and CPs (recommended) • FM • CP, point-to-point • PROFIBUS and Ethernet CPs Siemens ST 70 · 2011 6/7 6

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 412 ■ Technical specifications (continued) 6ES7 412-1XJ05-0AB0 6ES7 412-2XJ05-0AB0 6ES7 412-2EK06-0AB0 31; Max. 31 with alarm_S and alarm_D (OP's); max. 8 with alarm_8 and alarm_P (e.g. WinCC) 31; Max. 31 with alarm_S and alarm_D (OP's); max. 8 with alarm_8 and alarm_P (e.g. WinCC) 47; Max. 47 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC) Symbol-related messages Yes Yes Yes SCAN procedure Yes Yes Yes Number of messages • overall, max. 512 512 512 Block related messages Yes Yes Yes Process diagnostic messages Yes Yes Yes Alarm 8-blocks Yes Yes Yes Process control messages Yes Yes Yes Test commissioning functions Status/control • Status/control variable Yes; Up to 16 variable tables Yes; Up to 16 variable tables Yes; Up to 16 variable tables Forcing • Forcing Yes Yes Yes Status block Yes; Up to 2 simultaneously Yes; Up to 2 simultaneously Yes; Up to 16 simultaneously Single step Yes Yes Yes Number of breakpoints 4 4 16 Diagnostic buffer • present • Number of entries, max. - adjustable - preset Yes 200 Yes 120 Yes 400 Yes 120 Yes 400 Yes 120 S7 message functions Number of login stations for message functions, max. 6 Service data • can be read out Yes Communication functions PG/OP communication Yes Yes Yes Data record routing Yes Yes Yes Routing Yes; S7 routing Yes; S7 routing Yes; S7 routing Global data communication • supported • Size of GD packets, max. Yes 54 byte Yes 54 byte Yes 54 byte S7 basic communication • supported • User data per job, max. Yes 76 byte Yes 76 byte Yes 76 byte S7 communication • supported • as server • as client • User data per job, max. Yes Yes Yes 64 Kibyte Yes Yes Yes 64 Kibyte Yes Yes Yes 64 Kibyte • User data per job, max. Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 8 Kibyte Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 8 Kibyte Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 8 Kibyte Standard communication (FMS) • supported Yes; Via CP and loadable FB Yes; Via CP and loadable FB Yes; Via CP and loadable FB S5-compatible communication • supported 6/8 Siemens ST 70 · 2011

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 412 ■ Technical specifications (continued) 6ES7 412-1XJ05-0AB0 Web server • supported • Number of HTTP clients • User-defined websites 6ES7 412-2XJ05-0AB0 6ES7 412-2EK06-0AB0 No No Yes 5 Yes Open IE communication • TCP/IP - Number of connections, max. - Data length, max. - Several passive connections per port, supported • ISO-on-TCP (RFC1006) - Number of connections, max. - Data length, max. Yes; Via integrated PROFINET interface and loadable FBs 46 32 Kibyte Yes Via CP 443-1 Adv. and loadable FB Via CP 443-1 and loadable FB 1452 bytes via CP 443-1 Adv. 1452 bytes via CP 443-1 Adv. • UDP - Number of connections, max. - Data length, max. Number of connections • overall PROFINET CBA (at set setpoint communication load) • Number of remote interconnection partners • Number of functions, master/slave • Total of all Master/Slave connections • Data length of all incoming connections master/slave, max. • Data length of all outgoing connections master/slave, max. • Number of device-internal and PROFIBUS interconnections • Data length of device-internal and PROFIBUS interconnections, max. • Data length per connection, max. • Remote interconnections with acyclic transmission - Sampling frequency: Sampling time, min. - Number of incoming interconnections - Number of outgoing interconnections - Data length of all incoming interconnections, max. - Data length of all outgoing interconnections, max. - Data length per connection, max. 32 32 Yes; Via integrated PROFINET interface or CP 443-1 Adv. and loadable FBs 46 32 Kibyte; 1452 bytes via CP 443-1 Adv. Yes; Via integrated PROFINET interface and loadable FBs 46 1 472 byte 48 32 150 4 500 45 000 byte 45 000 byte 1 000 16 000 byte 2 000 byte 200 ms; Depending on preset communcation load, number of interconnections and data length used 250 250 8 000 byte 8 000 byte 2 000 byte Siemens ST 70 · 2011 6/9 6

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 412 ■ Technical specifications (continued) 6ES7 412-1XJ05-0AB0 6ES7 412-2XJ05-0AB0 • Remote interconnections with cyclic transmission - Transmission frequency: Transmission interval, min. 6 6ES7 412-2EK06-0AB0 1 ms; Depending on preset communication load, number of interconnections and data length used 300 - Number of incoming interconnections - Number of outgoing interconnections - Data length of all incoming interconnections, max. - Data length of all outgoing interconnections, max. - Data length per connection, max. • HMI variables via PROFINET (acyclic) - Number of stations that can log on for HMI variables (PN OPC/iMap) - HMI variable updating - Number of HMI variables - Data length of all HMI variables, max. • PROFIBUS proxy functionality - supported 300 4 800 byte 4 800 byte 450 byte 2x PN OPC/1x iMap 500 ms 1 000 32 000 byte Yes; 32 PROFIBUS slaves max. connectable 240 byte; Slave-dependent - Data length per connection, max. 1st interface Type of interface Integrated Integrated Integrated Physics RS 485 / PROFIBUS + MPI RS 485 / PROFIBUS + MPI RS 485 / PROFIBUS + MPI Isolated Yes Yes Yes Power supply to interface (15 to 30 V DC), max. 150 mA 150 mA 150 mA Number of connection resources MPI: 32, DP: 16 MPI: 32, DP: 16 MPI: 32, DP: 16 Functionality • MPI • DP master • DP slave Yes Yes Yes Yes Yes Yes Yes Yes Yes 32; if a diagnostic repeater is used on the line, the number of connection resources on the line is reduced by 1 32; if a diagnostic repeater is used on the line, the number of connection resources on the line is reduced by 1 32; if a diagnostic repeater is used on the line, the number of connection resources on the line is reduced by 1 Yes Yes Yes Yes Yes Yes Yes 12 Mbit/s Yes Yes Yes Yes Yes Yes Yes 12 Mbit/s Yes Yes Yes Yes Yes Yes Yes 12 Mbit/s MPI • Number of connections • Services - PG/OP communication - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server • Transmission rate, max. 6/10 Siemens ST 70 · 2011

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 412 ■ Technical specifications (continued) 6ES7 412-1XJ05-0AB0 DP master • Number of connections, max. • Services - PG/OP communication - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support - Isochronous mode - SYNC/FREEZE - Activation/deactivation of DP slaves - Direct data exchange (slave-to-slave communication) - DPV1 • Transmission rate, max. • Number of DP slaves, max. • Address area - Inputs, max. - Outputs, max. • User data per DP slave - User data per DP slave, max. - Inputs, max. - Outputs, max. - Slots, max. - per slot, max. DP slave • Number of connections • Services - PG/OP communication - S7 routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Direct data exchange (slave-to-slave communication) - DPV1 • GSD file • Transmission rate, max. • Automatic baud rate search • Transfer memory - Inputs - Outputs • Address area, max. • User data per address area, max. • User data per address area, of which consistent, max. 6ES7 412-2XJ05-0AB0 6ES7 412-2EK06-0AB0 16; if a diagnostic repeater is used on the line, the number of connection resources on the line is reduced by 1 16; if a diagnostic repeater is used on the line, the number of connection resources on the line is reduced by 1 16; if a diagnostic repeater is used on the line, the number of connection resources on the line is reduced by 1 Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 12 Mbit/s 32 Yes 12 Mbit/s 32 Yes 12 Mbit/s 32 2 Kibyte 2 Kibyte 2 Kibyte 2 Kibyte 2 Kibyte 2 Kibyte 244 byte 244 byte 244 byte 244 128 byte 244 byte 244 byte 244 byte 244 128 byte 244 byte 244 byte 244 byte 244 128 byte 16 16 16 Yes; with interface active Yes; With interface active No No Yes Yes Yes No Yes; with interface active Yes; With interface active No No Yes Yes Yes No Yes; with interface active Yes; With interface active No No Yes Yes Yes No No http://support.automation.siemens. com/WW/view/en/113652 12 Mbit/s No No http://support.automation.siemens. com/WW/view/en/113652 12 Mbit/s No No http://support.automation.siemens. com/WW/view/en/113652 12 Mbit/s No 244 byte 244 byte 32; Virtual slots 32 byte 32 byte 244 byte 244 byte 32; Virtual slots 32 byte 32 byte 244 byte 244 byte 32; Virtual slots 32 byte 32 byte Siemens ST 70 · 2011 6 6/11

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 412 ■ Technical specifications (continued) 6ES7 412-1XJ05-0AB0 6ES7 412-2XJ05-0AB0 6ES7 412-2EK06-0AB0 2nd interface Type of interface Integrated PROFINET Physics RS 485 / PROFIBUS Ethernet RJ45 Isolated Yes Yes Integrated switch Yes Number of ports Power supply to interface (15 to 30 V DC), max. 2 150 mA Automatic detection of transmission speed Autonegotiation Yes Autocrossing 6 Yes; Autosensing Yes Media redundancy • supported • Switchover time on line break, typically • Number of stations in the ring, max. Yes 200 ms 50 Change of IP address at runtime, supported Number of connection resources Functionality • DP master • DP slave • PROFINET IO controller • PROFINET IO device • PROFINET CBA • Open IE communication • Web server - Number of HTTP clients • Local Operating Network DP master • Number of connections, max. • Services - PG/OP communication - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support - Isochronous mode - SYNC/FREEZE - Activation/deactivation of DP slaves - Direct data exchange (slave-to-slave communication) - DPV1 • Transmission rate, max. • Number of DP slaves, max. • Address area - Inputs, max. - Outputs, max. 6/12 Siemens ST 70 · 2011 Yes; Assignment by higher-level IO controller or by the user program with SFB104 "IP_CONF" 16 48 Yes Yes No No Yes Yes Yes Yes Yes 5 No 16 Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 12 Mbit/s 64 4 Kibyte 4 Kibyte

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 412 ■ Technical specifications (continued) 6ES7 412-1XJ05-0AB0 • User data per DP slave - User data per DP slave, max. - Inputs, max. - Outputs, max. - Slots, max. - per slot, max. DP slave • Number of connections • Services - Routing - Programming • GSD file • Transmission rate, max. • Transfer memory - Inputs - Outputs • Address area, max. • User data per address area, max. • User data per address area, of which consistent, max. PROFINET IO controller • Services - PG/OP communication - S7 routing - S7 communication - Isochronous mode - Open IE communication • Transmission rate, min. • Transmission rate, max. • Number of connectable IO devices, max. • Max. number of connectable IO devices for RT - of which in line, max. • Number of IO devices with IRT and the option "high flexibility" - of which in line, max. • Number of IO devices with IRT and the option "high performance", max. - of which in line, max. • IRT, supported • Shared device, supported • Prioritized startup supported - Number of IO devices, max. • Activation/deactivation of IO devices - Number of IO devices that can be simultaneously activated/deactivated, max. • IO devices changing during operation (partner ports), supported - Max. number of IO devices per tool 6ES7 412-2XJ05-0AB0 6ES7 412-2EK06-0AB0 244 byte 244 byte 244 byte 244 128 byte 16 Yes Yes http://support.automation.siemens. com/WW/view/en/113652 12 Mbit/s 244 byte 244 byte 32 32 byte 32 byte 6 Yes Yes Yes Yes; Only with IRT and the High Performance option Yes 10 Mbit/s 100 Mbit/s 256 256 256 256 61 64 64 Yes Yes Yes 32 Yes 8 Yes 8; 8 parallel calls of the SFC 12 "D_ACT_DP" possible per line. Max. 32 IO devices changing during operation (partner ports) are supported. Siemens ST 70 · 2011 6/13

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 412 ■ Technical specifications (continued) 6ES7 412-1XJ05-0AB0 6ES7 412-2XJ05-0AB0 • Device replacement without swap medium • Send clock times Yes 250 Ps, 500 Ps, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 μs to 4 ms in 125 μs frame 250 μs to 512 ms; minimum value depends on preset communication share for PROFINET IO, on the number of IO devices and on the amount of configured user data, see PROFINET system description • Updating time • Address area - Inputs, max. - Outputs, max. • User data per address area, max. - User data consistency, max. 6 6ES7 412-2EK06-0AB0 4 Kibyte 4 Kibyte 1 024 byte PROFINET IO device • Services - PG/OP communication - S7 routing - S7 communication - Isochronous mode - Open IE communication - IRT, supported - Prioritized startup supported - Shared device, supported - Number of IO controllers with shared device, max. • Transfer memory - Inputs, max. Yes Yes Yes No Yes Yes Yes Yes 2 1 440 byte; Per IO controller with shared device 1 440 byte; Per IO controller with shared device - Outputs, max. • Submodules - Number, max. - User data per submodule, max. 64 1 024 byte PROFINET CBA • acyclic transmission • cyclic transmission Yes Yes Open IE communication • Open IE communication, supported • Number of connections, max. • Local port numbers used at the system end Yes 46 0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535 Yes • Keep-alive function, supported Isochronous mode Isochronous mode Yes; For PROFIBUS only Yes; For PROFIBUS only Yes; Via PROFIBUS DP or PROFINET interface Number of DP masters with isochronous mode 1 2 1 User data per isochronous slave, max. 244 byte 244 byte 244 byte Equidistance Yes Yes Yes Shortest clock pulse 1.5 ms; 0.5 ms without use of SFC 126, 127 1.5 ms; 0.5 ms without use of SFC 126, 127 1.5 ms; 0.5 ms without use of SFC 126, 127 Max. cycle 32 ms 32 ms 32 ms 6/14 Siemens ST 70 · 2011

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 412 ■ Technical specifications (continued) 6ES7 412-1XJ05-0AB0 6ES7 412-2XJ05-0AB0 6ES7 412-2EK06-0AB0 100 ms 100 ms 100 ms 30 μs; Time per I/O byte 200 μs; Time per I/O byte 30 μs; Time per I/O byte Programming Configuration software • STEP 7 Yes Yes Yes Programming language • STEP 7 • LAD • FBD • STL • SCL • CFC • GRAPH • HiGraph® Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Nesting levels 7 7 7 Yes Yes Yes CiR - Configuration in RUN CiR synchronization time, basic load CiR synchronization time, time per I/O slave Know-how protection • User program protection/password protection • Block encryption EMC Emission of radio interference acc. to EN 55 011 • Limit value class A, for use in industrial areas • Limit value class B, for use in residential areas 6 Yes; With S7 block privacy Yes Yes No No Dimensions Required slots 1 1 1 Dimensions and weight Dimensions • Width • Height • Depth 25 mm 290 mm 219 mm 25 mm 290 mm 219 mm 25 mm 290 mm 219 mm Weight • Weight, approx. 0.7 kg 0.7 kg 750 g Siemens ST 70 · 2011 6/15

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 412 ■ Ordering data Order No. 6ES7 412-1XJ05-0AB0 CPU 412-1 Work memory 288 KB, power supply 24 V DC, MPI/PROFIBUS DP master interface, slot for memory card, incl. slot number labels CPU 412-2 German 6ES7 398-8EA00-8CA0 Spanish 6ES7 398-8EA00-8DA0 Italian SIMATIC manual collection 6ES7 412-2EK06-0AB0 Work memory 1 MB, power supply 24 V DC, MPI/PROFIBUS DP master interface, PROFINET interface, slot for memory card, incl. slot number labels Memory card RAM 6 6ES7 398-8EA00-8BA0 French Work memory 512 KB, power supply 24 V DC, MPI/PROFIBUS DP master interface, slot for memory card, incl. slot number labels 6ES7 398-8EA00-8AA0 English 6ES7 412-2XJ05-0AB0 CPU 412-2 PN Order No. Manual "Communication for SIMATIC S7-300/-400" 6ES7 398-8EA00-8EA0 J 6ES7 998-8XC01-8YE0 D 6ES7 998-8XC01-8YE2 Electronic manuals on DVD, multilingual: LOGO!, SIMADYN, SIMATIC bus components, SIMATIC C7, SIMATIC distributed I/O, SIMATIC HMI, SIMATIC Sensors, SIMATIC NET, SIMATIC PC Based Automation, SIMATIC PCS 7, SIMATIC PG/PC, SIMATIC S7, SIMATIC Software, SIMATIC TDC SIMATIC manual collection update service for 1 year 64 KB 6ES7 952-0AF00-0AA0 256 KB 6ES7 952-1AH00-0AA0 1 MB 6ES7 952-1AK00-0AA0 2 MB 6ES7 952-1AL00-0AA0 4 MB 6ES7 952-1AM00-0AA0 8 MB 6ES7 952-1AP00-0AA0 Brochure "SIMATIC S7-400 programmable controller Design and application" 16 MB 6ES7 952-1AS00-0AA0 German 6ES7 498-8AA00-8AB0 64 MB 6ES7 952-1AY00-0AA0 English 6ES7 498-8AA00-8BB0 FEPROM memory card Current "Manual Collection" DVD and the three subsequent updates RS 485 bus connector with 90° cable outlet 64 KB 6ES7 952-0KF00-0AA0 256 KB 6ES7 952-0KH00-0AA0 1 MB 6ES7 952-1KK00-0AA0 2 MB 6ES7 952-1KL00-0AA0 4 MB 6ES7 952-1KM00-0AA0 RS 485 bus connector with angled cable outlet 8 MB 6ES7 952-1KP00-0AA0 Max. transfer rate 12 Mbit/s 16 MB 6ES7 952-1KS00-0AA0 Without PG interface 6ES7 972-0BA42-0XA0 32 MB 6ES7 952-1KT00-0AA0 With PG interface 6ES7 972-0BB42-0XA0 64 MB 6ES7 952-1KY00-0AA0 MPI cable 6ES7 901-0BF00-0AA0 RS 485 bus connector with 90° cable outlet for Fast Connect system for connection of SIMATIC S7 and PG via MPI; 5 m in length Slot number labels Max. transfer rate 12 Mbit/s Without PG interface 6ES7 972-0BA12-0XA0 With PG interface 6ES7 972-0BB12-0XA0 Max. transfer rate 12 Mbit/s 1 set (spare part) Manual "SIMATIC S7-400 programmable controller" incl. instruction list German 6ES7 498-8AA05-8AA0 English 6ES7 498-8AA05-8BA0 S7-400 operation list German 6ES7 498-8AA05-8AN0 English 6ES7 498-8AA05-8BN0 Without PG interface • 1 unit • 100 units 6ES7 972-0BA52-0XA0 6ES7 972-0BA52-0XB0 With PG interface • 1 unit • 100 units 6ES7 912-0AA00-0AA0 6ES7 972-0BB52-0XA0 6ES7 972-0BB52-0XB0 RS 485 bus connector with axial cable outlet For SIMATIC OP, for connection to PPI, MPI, PROFIBUS 6GK1 500-0EA02 PROFIBUS FastConnect bus cable Standard type with special design for quick mounting, 2-core, shielded, sold by the meter, max. delivery unit 1000 m, minimum ordering quantity 20 m 6XV1 830-0EH10 D: Subject to export regulations AL: N and ECCN: 5D992 J: Subject to export regulations AL: N and ECCN: EAR99S 6/16 Siemens ST 70 · 2011

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 414 ■ Overview • CPUs for high demands in the mid-level performance range • Applicable for plants with additional demands on programming scope and processing speed • Integrated PROFINET functions in CPU 414-3 PN/DP ■ Technical specifications 6 6ES7 414-2XK05-0AB0 6ES7 414-3XM05-0AB0 6ES7 414-3EM06-0AB0 Product type designation CPU 414-2 CPU 414-3 CPU414-3 PN/DP Product version Hardware product version 03 03 01 Firmware version V5.3 V5.3 V6.0 associated programming package STEP7 V 5.3 SP2 or higher with HW update STEP7 V 5.3 SP2 or higher with HW update STEP7 V5.5 or higher/iMap V3.0 + iMap STEP7 Add-on V3.0 SP5 or higher No; Power supply via system power supply No; Power supply via system power supply No; Power supply via system power supply 5 to 15 V DC 5 to 15 V DC 5 to 15 V DC Current consumption from backplane bus 5 V DC, max. 1.1 A 1.3 A 1.5 A from interface 5 V DC, max. 90 mA; At each DP interface 90 mA; At each DP interface 90 mA; At each DP interface Power losses Power loss, typ. 4.5 W 5.5 W 6.5 W Power loss, max. 5W 6W 7.5 W Backup battery Battery operation • Backup current, typ. • Backup current, max. not relevant 125 μA; (up to 40 °C) 550 μA not relevant 125 μA 550 μA not relevant 125 μA; (up to 40 °C) 450 μA Memory Work memory • integrated (for program) • integrated (for data) • expandable 0.5 Mbyte 0.5 Mbyte No 1.4 Mbyte 1.4 Mbyte No 2 Mbyte 2 Mbyte No Load memory • expandable FEPROM • expandable FEPROM, max. • integrated RAM, max. • expandable RAM • expandable RAM, max. Yes; with Memory Card (FLASH) 64 Mbyte 512 Kibyte Yes; with Memory Card (RAM) 64 Mbyte Yes; with Memory Card (FLASH) 64 Mbyte 512 Kibyte Yes; with Memory Card (RAM) 64 Mbyte Yes; with Memory Card (FLASH) 64 Mbyte 512 Kibyte Yes; with Memory Card (RAM) 64 Mbyte Backup • present • with battery • without battery Yes Yes; All data No Yes Yes; All data No Yes Yes; All data No Supply voltages Rated value • 24 V DC Feeding of external backup voltage to CPU Siemens ST 70 · 2011 6/17

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 414 ■ Technical specifications (continued) 6ES7 414-2XK05-0AB0 6ES7 414-3EM06-0AB0 CPU-blocks DB • Number, max. • Size, max. 6 000; Number range: 1 to 16,000 64 Kibyte 6 000; Number range: 1 to 16,000 64 Kibyte 6 000; Number range: 1 to 16,000 64 Kibyte FB • Number, max. • Size, max. 3 000; Number range: 0 to 7999 64 Kibyte 3 000; Number range: 0 to 7999 64 Kibyte 3 000; Number range: 0 to 7999 64 Kibyte FC • Number, max. • Size, max. 3 000; Number range: 0 to 7999 64 Kibyte 3 000; Number range: 0 to 7999 64 Kibyte 3 000; Number range: 0 to 7999 64 Kibyte OB • Size, max. 64 Kibyte 64 Kibyte 64 Kibyte Nesting depth • per priority class • additional within an error OB 6 6ES7 414-3XM05-0AB0 24 1 24 1 24 1 CPU processing times for bit operations, min. 45 ns 45 ns 45 ns for word operations, min. 45 ns 45 ns 45 ns for fixed point arithmetic, min. 45 ns 45 ns 45 ns for floating point arithmetic, min. 135 ns 135 ns 135 ns 2 048 2 048 2 048 Yes 0 2 047 Z 0 to Z 7 Yes 0 2 047 Z 0 to Z 7 Yes 0 2 047 Z 0 to Z 7 0 999 0 999 0 999 Yes SFB Unlimited (limited only by work memory) Yes SFB Unlimited (limited only by work memory) Yes SFB Unlimited (limited only by work memory) 2 048 2 048 2 048 Yes 0 2 047 No times retentive Yes 0 2 047 No times retentive Yes 0 2 047 No times retentive 10 ms 9 990 s 10 ms 9 990 s 10 ms 9 990 s Yes SFB Unlimited (limited only by work memory) Yes SFB Unlimited (limited only by work memory) Yes SFB Unlimited (limited only by work memory) Counters, timers and their retentivity S7 counter • Number • Retentivity - adjustable - lower limit - upper limit - preset • Counting range - lower limit - upper limit IEC counter • Present • Type • Number S7 times • Number • Retentivity - adjustable - lower limit - upper limit - preset • Time range - lower limit - upper limit IEC timer • present • Type • Number 6/18 Siemens ST 70 · 2011

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 414 ■ Technical specifications (continued) 6ES7 414-2XK05-0AB0 6ES7 414-3XM05-0AB0 6ES7 414-3EM06-0AB0 Total working and load memory (with backup battery) Total working and load memory (with backup battery) Total working and load memory (with backup battery) • Retentivity available • Number of clock memories 8 Kibyte; Size of bit memory address area Yes 8; (in 1 memory byte) 8 Kibyte; Size of bit memory address area Yes 8; (in 1 memory byte) 8 Kibyte; Size of bit memory address area Yes 8; (in 1 memory byte) Data blocks • Number, max. • Size, max. 6 000; Number range: 1 to 16,000 64 Kibyte 6 000; Number range: 1 to 16,000 64 Kibyte 6 000; Number range: 1 to 16,000 64 Kibyte Local data • adjustable, max. • preset 16 Kibyte 8 Kibyte 16 Kibyte 8 Kibyte 16 Kibyte 8 Kibyte 8 Kibyte 8 Kibyte 8 Kibyte 8 Kibyte 8 Kibyte 8 Kibyte 2 Kibyte 2 Kibyte 6 Kibyte 6 Kibyte 2 Kibyte 2 Kibyte 6 Kibyte 6 Kibyte 2 Kibyte 2 Kibyte 6 Kibyte 6 Kibyte 8 Kibyte 8 Kibyte Process image • Inputs, adjustable • Outputs, adjustable • Inputs, preset • Outputs, preset • consistent data, max. • Access to consistent data in process image 8 Kibyte 8 Kibyte 256 byte 256 byte 244 byte Yes 8 Kibyte 8 Kibyte 256 byte 256 byte 244 byte Yes 8 Kibyte 8 Kibyte 256 byte 256 byte 244 byte Yes Subprocess images • Number of subprocess images, max. 15 15 15 Digital channels • Inputs • Outputs • Inputs, of which central • Outputs, of which central 65 536 65 536 65 536 65 536 65 536 65 536 65 536 65 536 65 536 65 536 65 536 65 536 Analog channels • Inputs • Outputs • Inputs, of which central • Outputs, of which central 4 096 4 096 4 096 4 096 4 096 4 096 4 096 4 096 4 096 4 096 4 096 4 096 Hardware configuration connectable OPs 31 31 63 Central devices, max. 1 1 1 Expansion devices, max. 21 21 21 Multicomputing Yes; 4 CPUs max. (with UR1 or UR2) Yes; 4 CPUs max. (with UR1 or UR2) Yes; 4 CPUs max. (with UR1 or UR2) 6 6 6 6 6 6 4; IM 463-2 4; IM 463-2 4; IM 463-2 Data areas and their retentivity retentive data area, total Flag • Number, max. Address area I/O address area • overall • Outputs • of which, distributed - MPI/DP interface, inputs - MPI/DP interface, outputs - DP interface, inputs - DP interface, outputs - PN interface, inputs - PN interface, outputs Interface modules • Number of connectable IMs (total), max. • Number of connectable IM 460s, max. • Number of connectable IM 463s, max. Siemens ST 70 · 2011 6 6/19

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 414 ■ Technical specifications (continued) 6ES7 414-2XK05-0AB0 6ES7 414-3XM05-0AB0 6ES7 414-3EM06-0AB0 2 4 10; CP 443-5 Extended No; IM 467 not suitable for use with CP 443-5 Ext. and CP443-1 EX4x, EX20, GX20 (in PNIO mode) 0 6 2 4 10; CP 443-5 Extended No; IM 467 not suitable for use with CP 443-5 Ext. and CP443-1 EX4x, EX20, GX20 (in PNIO mode) 1 6 1 4 10; CP 443-5 Extended No; IM 467 not suitable for use with CP 443-5 Ext. and CP443-1 EX4x, EX20, GX20 (in PNIO mode) 1; IF 964-DP 6 0 4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/ GX20, max. 4 in central controller 0 4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/ GX20, max. 4 in central controller 1 4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/ GX20, max. 4 in central controller Limited by number of slots and number of connections CP 440: limited by number of slots; CP 441: limited by number of connections 14; Of which 10 CPs max. or IMs as DP master, 4 PN controller maximum Limited by number of slots and number of connections CP 440: limited by number of slots; CP 441: limited by number of connections 14; Of which 10 CPs max. or IMs as DP master, 4 PN controller maximum Limited by number of slots and number of connections CP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections 14; In total max. 10 CPs as DP master and PN controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PN controller Time Clock • Hardware clock (real-time clock) Yes • Battery-backed and synchronizable Yes • Resolution 1 ms Yes Yes 1 ms Yes Yes 1 ms Runtime meter • Number 16 16 16 Clock synchronization • supported • to MPI, master • to MPI, slave • to DP, master • to DP, slave • in AS, master • in AS, slave • on Ethernet via NTP • to IF 964 DP Yes Yes Yes Yes Yes Yes Yes No; via CP No Yes Yes Yes Yes Yes Yes Yes No; via CP Yes Yes Yes Yes Yes Yes Yes Yes Yes; as client Yes 31; max. 31 with alarm_S and alarm_D (OP's); max. 8 with alarm_8 and alarm_P (e.g. WinCC) 31; max. 31 with alarm_S and alarm_D (OP's); max. 8 with alarm_8 and alarm_P (e.g. WinCC) 63; max. 63 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC) Symbol-related messages Yes Yes Yes SCAN procedure Yes Yes Yes Number of messages • overall, max. 512 512 512 Block related messages Yes Yes Yes Process diagnostic messages Yes Yes Yes Alarm 8-blocks Yes Yes Yes Process control messages Yes Yes Yes Number of DP masters • integrated • via IM 467 • via CP • Mixed mode IM + CP permitted • via interface module • Number of pluggable S5 modules (via adapter capsule in central device), max. Number of IO controllers • integrated • via CP 6 Number of operable FMs and CPs (recommended) • FM • CP, point-to-point • PROFIBUS and Ethernet CPs S7 message functions Number of login stations for message functions, max. 6/20 Siemens ST 70 · 2011

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 414 ■ Technical specifications (continued) 6ES7 414-2XK05-0AB0 6ES7 414-3XM05-0AB0 6ES7 414-3EM06-0AB0 Test commissioning functions Status/control • Status/control variable Yes; Up to 16 variable tables Yes; Up to 16 variable tables Yes; Up to 16 variable tables Forcing • Forcing Yes Yes Yes Status block Yes; Up to 2 simultaneously Yes; Up to 2 simultaneously Yes; Up to 16 simultaneously Single step Yes Yes Yes Number of breakpoints 4 4 16 Diagnostic buffer • present • Number of entries, max. - adjustable - preset Yes 400 Yes 120 Yes 3 200 Yes 120 Yes 3 200 Yes 120 Service data • can be read out Yes Communication functions PG/OP communication Yes Yes Yes Data record routing Yes Yes Yes Routing Yes; S7 routing Yes; S7 routing Yes; S7 routing Global data communication • supported • Size of GD packets, max. Yes 54 byte Yes 54 byte Yes 54 byte S7 basic communication • supported • User data per job, max. Yes 76 byte Yes 76 byte Yes 76 byte S7 communication • supported • as server • as client • User data per job, max. Yes Yes Yes 64 Kibyte Yes Yes Yes 64 Kibyte Yes Yes Yes 64 Kibyte • User data per job, max. Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 8 Kibyte Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 8 Kibyte Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 8 Kibyte Standard communication (FMS) • supported Yes; Via CP and loadable FB Yes; Via CP and loadable FB Yes; Via CP and loadable FB No No Yes 5 Yes S5-compatible communication • supported Web server • supported • Number of HTTP clients • User-defined websites Open IE communication • TCP/IP - Number of connections, max. - Data length, max. - Several passive connections per port, supported 6 Yes; Via integrated PROFINET interface and loadable FBs 62 32 Kibyte Yes Siemens ST 70 · 2011 6/21

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 414 ■ Technical specifications (continued) 6ES7 414-2XK05-0AB0 • ISO-on-TCP (RFC1006) - Number of connections, max. - Data length, max. 6ES7 414-3XM05-0AB0 6ES7 414-3EM06-0AB0 Via CP 443-1 and loadable FB Via CP 443-1 and loadable FB 1452 bytes via CP 443-1 Adv. 1452 bytes via CP 443-1 Adv. Yes; Via integrated PROFINET interface or CP 443-1 Adv. and loadable FBs 62 32 Kibyte; 1452 bytes via CP 443-1 Adv. Yes; Via integrated PROFINET interface and loadable FBs 62 1 472 byte 32 32 • UDP - Number of connections, max. - Data length, max. Number of connections • overall 6 PROFINET CBA (at set setpoint communication load) • Number of remote interconnection partners • Number of functions, master/slave • Total of all Master/Slave connections • Data length of all incoming connections master/slave, max. • Data length of all outgoing connections master/slave, max. • Number of device-internal and PROFIBUS interconnections • Data length of device-internal and PROFIBUS interconnections, max. • Data length per connection, max. • Remote interconnections with acyclic transmission - Sampling frequency: Sampling time, min. - Number of incoming interconnections - Number of outgoing interconnections - Data length of all incoming interconnections, max. - Data length of all outgoing interconnections, max. - Data length per connection, max. • Remote interconnections with cyclic transmission - Transmission frequency: Transmission interval, min. - Number of incoming interconnections - Number of outgoing interconnections - Data length of all incoming interconnections, max. - Data length of all outgoing interconnections, max. - Data length per connection, max. 6/22 Siemens ST 70 · 2011 64 32 150 4 500 45 000 byte 45 000 byte 1 000 16 000 byte 2 000 byte 200 ms; Depending on preset communcation load, number of interconnections and data length used 250 250 8 000 byte 8 000 byte 2 000 byte 1 ms; Depending on preset communication load, number of interconnections and data length used 300 300 4 800 byte 4 800 byte 450 byte

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 414 ■ Technical specifications (continued) 6ES7 414-2XK05-0AB0 6ES7 414-3XM05-0AB0 • HMI variables via PROFINET (acyclic) - Number of stations that can log on for HMI variables (PN OPC/iMap) - HMI variable updating - Number of HMI variables - Data length of all HMI variables, max. • PROFIBUS proxy functionality - supported 6ES7 414-3EM06-0AB0 2x PN OPC/1x iMap 500 ms 1 000 32 000 byte Yes; 32 PROFIBUS slaves max. connectable 240 byte; Slave-dependent - Data length per connection, max. 1st interface Type of interface Integrated Integrated Integrated Physics RS 485 / PROFIBUS + MPI RS 485 / PROFIBUS + MPI RS 485 / PROFIBUS + MPI Isolated Yes Yes Yes Power supply to interface (15 to 30 V DC), max. 150 mA 150 mA 150 mA Number of connection resources MPI: 32, DP: 16 MPI: 32, DP: 16 MPI: 32, DP: 16 Functionality • MPI • DP master • DP slave Yes Yes Yes Yes Yes Yes Yes Yes Yes 32; if a diagnostic repeater is used on the line, the number of connection resources on the line is reduced by 1 32; if a diagnostic repeater is used on the line, the number of connection resources on the line is reduced by 1 32; if a diagnostic repeater is used on the line, the number of connection resources on the line is reduced by 1 Yes Yes Yes Yes Yes Yes Yes 12 Mbit/s Yes Yes Yes Yes Yes Yes Yes 12 Mbit/s Yes Yes Yes Yes Yes Yes Yes 12 Mbit/s 16; if a diagnostic repeater is used on the line, the number of connection resources on the line is reduced by 1 16; if a diagnostic repeater is used on the line, the number of connection resources on the line is reduced by 1 16; if a diagnostic repeater is used on the line, the number of connection resources on the line is reduced by 1 Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes MPI • Number of connections • Services - PG/OP communication - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server • Transmission rate, max. DP master • Number of connections, max. • Services - PG/OP communication - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support - Isochronous mode - SYNC/FREEZE - Activation/deactivation of DP slaves - Direct data exchange (slave-to-slave communication) - DPV1 Siemens ST 70 · 2011 6 6/23

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 414 ■ Technical specifications (continued) 6ES7 414-2XK05-0AB0 6ES7 414-3XM05-0AB0 6ES7 414-3EM06-0AB0 12 Mbit/s 32 12 Mbit/s 32 12 Mbit/s 32 2 Kibyte 2 Kibyte 2 Kibyte 2 Kibyte 2 Kibyte 2 Kibyte 244 byte 244 byte 244 byte 244 128 byte 244 byte 244 byte 244 byte 244 128 byte 244 byte 244 byte 244 byte 244 128 byte 16 16 16 Yes; with interface active Yes; With interface active No No Yes Yes Yes No Yes; with interface active Yes; With interface active No No Yes Yes Yes No Yes; with interface active Yes; With interface active No No Yes Yes Yes No No http://support.automation.siemens. com/WW/view/en/113652 12 Mbit/s No No http://support.automation.siemens. com/WW/view/en/113652 12 Mbit/s No No http://support.automation.siemens. com/WW/view/en/113652 12 Mbit/s No 244 byte 244 byte 32; Virtual slots 32 byte 32 byte 244 byte 244 byte 32; Virtual slots 32 byte 32 byte 244 byte 244 byte 32; Virtual slots 32 byte 32 byte 2nd interface Type of interface Integrated Integrated PROFINET Physics RS 485 / PROFIBUS RS 485 / PROFIBUS Ethernet RJ45 Isolated Yes Yes Yes • Transmission rate, max. • Number of DP slaves, max. • Address area - Inputs, max. - Outputs, max. • User data per DP slave - User data per DP slave, max. - Inputs, max. - Outputs, max. - Slots, max. - per slot, max. 6 DP slave • Number of connections • Services - PG/OP communication - S7 routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Direct data exchange (slave-to-slave communication) - DPV1 • GSD file • Transmission rate, max. • Automatic baud rate search • Transfer memory - Inputs - Outputs • Address area, max. • User data per address area, max. • User data per address area, of which consistent, max. Yes Integrated switch Number of ports Power supply to interface (15 to 30 V DC), max. 2 150 mA 150 mA Automatic detection of transmission speed Yes; Autosensing Autonegotiation Yes Autocrossing Yes Media redundancy • supported • Switchover time on line break, typically • Number of stations in the ring, max. Change of IP address at runtime, supported 6/24 Siemens ST 70 · 2011 Yes 200 ms 50 Yes; Assignment by higher-level IO controller or by the user program with SFB104 "IP_CONF"

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 414 ■ Technical specifications (continued) 6ES7 414-2XK05-0AB0 Number of connection resources Functionality • DP master • DP slave • PROFINET IO controller • PROFINET IO device • PROFINET CBA • Open IE communication • Web server - Number of HTTP clients • Local Operating Network DP master • Number of connections, max. • Services - PG/OP communication - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support - Isochronous mode - SYNC/FREEZE - Activation/deactivation of DP slaves - Direct data exchange (slave-to-slave communication) - DPV1 • Transmission rate, max. • Number of DP slaves, max. • Address area - Inputs, max. - Outputs, max. • User data per DP slave - User data per DP slave, max. - Inputs, max. - Outputs, max. - Slots, max. - per slot, max. DP slave • Number of connections • Services - Routing - Programming • GSD file • Transmission rate, max. • Transfer memory - Inputs - Outputs • Address area, max. • User data per address area, max. • User data per address area, of which consistent, max. 6ES7 414-3XM05-0AB0 6ES7 414-3EM06-0AB0 16 16 64 Yes Yes Yes Yes No No Yes Yes Yes Yes Yes 5 No 16 16 Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 12 Mbit/s 96 Yes 12 Mbit/s 96 6 Kibyte 6 Kibyte 6 Kibyte 6 Kibyte 244 byte 244 byte 244 byte 244 128 byte 244 byte 244 byte 244 byte 244 128 byte 16 16 Yes Yes http://support.automation.siemens. com/WW/view/en/113652 12 Mbit/s Yes Yes http://support.automation.siemens. com/WW/view/en/113652 12 Mbit/s 244 byte 244 byte 32 32 byte 32 byte 244 byte 244 byte 32 32 byte 32 byte 6 Siemens ST 70 · 2011 6/25

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 414 ■ Technical specifications (continued) 6ES7 414-2XK05-0AB0 PROFINET IO controller • Services - PG/OP communication - S7 routing - S7 communication - Isochronous mode 6 - Open IE communication • Transmission rate, min. • Transmission rate, max. • Number of connectable IO devices, max. • Max. number of connectable IO devices for RT - of which in line, max. • Number of IO devices with IRT and the option "high flexibility" - of which in line, max. • Number of IO devices with IRT and the option "high performance", max. - of which in line, max. • IRT, supported • Shared device, supported • Prioritized startup supported - Number of IO devices, max. • Activation/deactivation of IO devices - Number of IO devices that can be simultaneously activated/ deactivated, max. • IO devices changing during operation (partner ports), supported - Max. number of IO devices per tool • Device replacement without swap medium • Send clock times • Updating time • Address area - Inputs, max. - Outputs, max. • User data per address area, max. - User data consistency, max. 6/26 Siemens ST 70 · 2011 6ES7 414-3XM05-0AB0 6ES7 414-3EM06-0AB0 Yes Yes Yes Yes; only with IRT and the High Performance option Yes 10 Mbit/s 100 Mbit/s 256 256 256 256 61 64 64 Yes Yes Yes 32 Yes 8 Yes 8; 8 parallel calls of the SFC 12 "D_ACT_DP" possible per line. Max. 32 IO devices changing during operation (partner ports) are supported. Yes 250 Ps, 500 Ps, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 μs to 4 ms in 125 μs frame 250 μs to 512 ms; minimum value depends on preset communication share for PROFINET IO, on the number of IO devices and on the amount of configured user data, see PROFINET system description 8 Kibyte 8 Kibyte 1 024 byte

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 414 ■ Technical specifications (continued) 6ES7 414-2XK05-0AB0 6ES7 414-3XM05-0AB0 PROFINET IO device • Services - PG/OP communication - S7 routing - S7 communication - Isochronous mode - Open IE communication - IRT, supported - Prioritized startup supported - Shared device, supported - Number of IO controllers with shared device, max. • Transfer memory - Inputs, max. 6ES7 414-3EM06-0AB0 Yes Yes Yes No Yes Yes Yes Yes 2 1 440 byte; Per IO controller with shared device 1 440 byte; Per IO controller with shared device - Outputs, max. • Submodules - Number, max. - User data per submodule, max. 64 1 024 byte PROFINET CBA • acyclic transmission • cyclic transmission Yes Yes Open IE communication • Open IE communication, supported • Number of connections, max. • Local port numbers used at the system end Yes 62 0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535 Yes • Keep-alive function, supported 3rd interface Type of interface 6 Pluggable interface module (IF), technical specifications as for 2nd interface Pluggable interface module (IF) Plug-in interface modules IF 964-DP (MLFB: 6ES79642AA04-0AB0) IF 964-DP (MLFB: 6ES7964-2AA04-0AB0) Physics RS 485 / PROFIBUS RS 485 / PROFIBUS Isolated Yes Yes Power supply to interface (15 to 30 V DC), max. 150 mA 150 mA automatic detection of transmission speed No No Number of connection resources 16 16 Functionality • MPI • DP master • DP slave No Yes Yes No Yes Yes Siemens ST 70 · 2011 6/27

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 414 ■ Technical specifications (continued) 6ES7 414-2XK05-0AB0 6 DP master • Number of connections, max. • Services - PG/OP communication - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support - Isochronous mode - SYNC/FREEZE - Activation/deactivation of DP slaves - Direct data exchange (slave-to-slave communication) - DPV0 - DPV1 • Transmission rate, max. • Transmission rate, min. • Number of DP slaves, max. • Address area - Inputs, max. - Outputs, max. • User data per DP slave - User data per DP slave, max. - Inputs, max. - Outputs, max. - Slots, max. - per slot, max. DP slave • Number of connections • Services - PG/OP communication - S7 routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - SYNC/FREEZE - Direct data exchange (slave-to-slave communication) - DPV1 - Status/control • GSD file • Transmission rate, min. • Transmission rate, max. • Automatic baud rate search • Transfer memory - Inputs - Outputs • Address areas, max. • User data per address area, max. • User data per address area, of which consistent, max. 6/28 Siemens ST 70 · 2011 6ES7 414-3XM05-0AB0 6ES7 414-3EM06-0AB0 16 16 Yes Yes; S7 routing No No Yes Yes Yes Yes Yes Yes Yes Yes Yes; S7 routing No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 12 Mbit/s 9.6 kbit/s 96 Yes Yes 12 Mbit/s 9.6 kbit/s 96 6 Kibyte 6 Kibyte 6 Kibyte 6 Kibyte 244 byte 244 byte 244 byte 244 128 byte 244 byte 244 byte 244 byte 244 128 byte 16 16 Yes Yes; With active interface No No Yes Yes Yes No No Yes Yes; With active interface No No Yes Yes Yes No No No Yes; When interface active http://support.automation.siemens. com/WW/view/en/113652 9.6 kbit/s 12 Mbit/s No No Yes; When interface active http://support.automation.siemens. com/WW/view/en/113652 9.6 kbit/s 12 Mbit/s No 244 byte 244 byte 32 32 byte 32 byte 244 byte 244 byte 32; Virtual slots 32 byte 32 byte

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 414 ■ Technical specifications (continued) 6ES7 414-2XK05-0AB0 6ES7 414-3XM05-0AB0 6ES7 414-3EM06-0AB0 Yes; For PROFIBUS only Yes; For PROFIBUS only Yes; Via PROFIBUS DP or PROFINET interface Number of DP masters with isochronous mode 2 3 2 User data per isochronous slave, max. 244 byte 244 byte 244 byte Equidistance Yes Yes Yes Shortest clock pulse 1 ms; 0.5 ms without use of SFC 126, 127 1 ms; 0.5 ms without use of SFC 126, 127 1 ms; 0.5 ms without use of SFC 126, 127 Max. cycle 32 ms 32 ms 32 ms CiR - Configuration in RUN CiR synchronization time, basic load 100 ms 100 ms 100 ms 15 μs; Time per I/O byte 15 μs 15 μs; Time per I/O byte programming Configuration software • STEP 7 Yes Yes Yes Programming language • STEP 7 • LAD • FBD • STL • SCL • CFC • GRAPH • HiGraph® Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Nesting levels 7 7 7 Yes Yes Yes Isochronous mode Isochronous mode CiR synchronization time, time per I/O slave Know-how protection • User program protection/password protection • Block encryption 6 Yes; With S7 block Privacy EMC Emission of radio interference acc. to EN 55 011 • Limit value class A, for use in industrial areas • Limit value class B, for use in residential areas Yes No Dimensions Required slots 1 2 2 Dimensions and weight Dimensions • Width • Height • Depth 25 mm 290 mm 219 mm 50 mm 290 mm 219 mm 50 mm 290 mm 219 mm Weight • Weight, approx. 0.7 kg 0.9 kg 900 g Siemens ST 70 · 2011 6/29

© Siemens AG 2011 SIMATIC S7-400 Central processing units Standard CPUs CPU 414 ■ Ordering data Order No. 6ES7 414-2XK05-0AB0 CPU 414-2 Work memory 1 MB, power supply 24 V DC, MPI/PROFIBUS DP master interface, slot for memory card, incl. slot number labels CPU 414-3 Slot number labels Work memory 2.8 MB, power supply 24 V DC, MPI/PROFIBUS DP master interface, PROFIBUS DP master interface, slot for memory card, module slots for 1 IF module, incl. slot number labels 6 German 6ES7 414-3EM06-0AB0 6ES7 498-8AA05-8BA0 S7-400 operation list German 6ES7 498-8AA05-8AN0 English 6ES7 498-8AA05-8BN0 Manual "Communication for SIMATIC S7-300/-400" German 256 KB 6ES7 952-1AH00-0AA0 1 MB 6ES7 952-1AK00-0AA0 6ES7 952-1AL00-0AA0 6ES7 952-1AM00-0AA0 8 MB 6ES7 952-1AP00-0AA0 16 MB 6ES7 952-1AS00-0AA0 64 MB 6ES7 952-1AY00-0AA0 FEPROM memory card 64 KB 6ES7 952-0KF00-0AA0 256 KB 6ES7 952-0KH00-0AA0 1 MB 6ES7 952-1KK00-0AA0 2 MB 6ES7 952-1KL00-0AA0 4 MB 6ES7 952-1KM00-0AA0 8 MB 6ES7 952-1KP00-0AA0 16 MB 6ES7 952-1KS00-0AA0 32 MB 6ES7 952-1KT00-0AA0 64 MB 6ES7 952-1KY00-0AA0 MPI cable 6ES7 901-0BF00-0AA0 for connection of SIMATIC S7 and PG via MPI; 5 m in length 6ES7 498-8AA05-8AA0 English 6ES7 952-0AF00-0AA0 4 MB 1 set (spare part) incl. instruction list Memory card RAM 2 MB 6ES7 912-0AA00-0AA0 Manual "SIMATIC S7-400 programmable controller" Work memory 4 MB, power supply 24 V DC, MPI/PROF

Add a comment

Related presentations

Related pages

SIMATIC S7-400 - Steuerungen - Siemens

SIMATIC S7-400: stark für die ... PC-based Automation; Product Lifecycle Management Software; Prozessleitsysteme; ... CPU-Spektrums skalierbar, ...
Read more

S7-400 CPU - TP Automation e.K.

SIMATIC PC-based Controller; SIMATIC Field PG M4; ... SIMATIC S7-400, CPU 416-3 PN/DP Zentralbaugruppe mit: Arbeitsspeicher 16 MB, (8 MB Code, ...
Read more

SIMATIC Automation System S7-400 CPU Data

Automation System S7-400 CPU ... The SIMATIC S7-400 product range complies with ... • Installing and starting up STEP 7 on a programming device / PC
Read more

SIMATIC S7-300/S7-400 Schnittstelle CPU - CP

SIMATIC S7-300/S7-400 Ladbarer Treiber für Punkt-zu- ... 4.2 Installieren des Treibers auf dem STEP 7-PG/-PC ... 7 Schnittstelle CPU ...
Read more

Automation System S7-400, CPU Specifications - Siemens

• Installing and commissioning STEP 7 on a programming device / PC ... We offer various courses to newcomers to the SIMATIC S7 ... System S7-400 CPU ...
Read more

SIMATIC PCS 7 - siemens.de

SIMATIC PCS 7 CPU 410-5H Process Automation S7-400 CPU vs. CPU 410-5H ... SIMATIC Box PC (OS / ES / AS) IPC547E IPC427D IPC647D IPC847D IPC627D
Read more

SIMATIC S7-300 - Steuerungen - Siemens

Der modulare Controller SIMATIC S7-300 ist speziell für innovative Systemlösungen in der Fertigungsindustrie ... SIMATIC S7-400 go. ... PC-based Automation;
Read more

Simatic S7 CPU | eBay

Finden Sie tolle Angebote auf eBay für Simatic S7 CPU in SPS. ... Simatic Panel; Panel PC; ... Siemens Simatic S7-400 CPU 416-2 6ES7 416-2XK02-0AB0 mit ...
Read more

Simatic – Wikipedia

Simatic S7-400; Die größte SPS von ... optional in jede CPU integriert. Die ersten CPU sind die S7-1511, ... Simatic WinAC ergänzt Simatic S7 um PC ...
Read more

SIMATIC Controller - Die innovative Lösung für alle ...

SIMATIC SIMATIC Controller Die innovative Lösung für alle Automatisierungsaufgaben Answers for industry. Übersicht Ausgabe April 2013 Weitere Informationen
Read more