Select-eV shaping the future of GC-MS (HTC-13, 2014 conference)

50 %
50 %
Information about Select-eV shaping the future of GC-MS (HTC-13, 2014 conference)
Technology

Published on February 17, 2014

Author: markesint

Source: slideshare.net

Description

Presentation given at HTC-13 in Bruges, Belgium, on Markes' BenchTOF time-of-flight mass spectrometers for gas chromatography. As well as the features that make BenchTOF essential in the modern laboratory, the presentation describes Select-eV – newly launched variable-energy electron ionisation technology for GC–MS. Many examples are provided that illustrate how both classical reference-quality EI mass spectra at 70 eV and enhanced molecular ions at lower energies can enhance detection of challenging analytes – all without any loss in sensitivity.

Select-eV – Shaping the future of GC–MS Laura McGregor, Nick Bukowski

What is the BenchTOF? • A reflectron time-of-flight mass spectrometer • Platform-neutral • Innovative design

BenchTOF technology Innovative design Differentially pumped source and analyser chambers High accelerating voltage Direct extraction optimises sensitivity Multi-stage reflectron optimises resolution

The result… …exceptional sensitivity for trace analytes RT: 3.50 - 5.65 NL: 3.62E4 m/z= 271.50272.50 MS 100812_13_ dbc_100812 154612 5.23 100 90 80 Relative Abundance 70 OFN 1 pg 60 50 40 30 20 10 0 3.60 3.72 3.6 Base Peak Retention Time : 5.23 Scan : 628 Intensity : 36173 3.86 3.95 3.8 4.0 4.22 4.33 4.2 4.47 4.50 4.68 4.4 4.6 Time (min) 4.8 4.95 5.0 5.19 5.2 Calculated values Noise Range : 3.99 - 4.19 minutes (24 scans) Baseline : 6 Signal To Noise : 2747 Standard Deviation : 13 5.48 5.4 5.6

Exceptional sensitivity Trace-level pesticides (20 pg of aldrin; EIC m/z 263) SIM quadrupole S/N ratio: 41 2 pg on column S/N ratio: 30 BenchTOF S/N ratio: 380

Variable-energy electron ionisation with no loss in sensitivity

Advantages of Select-eV ionisation • No source exchanges or reagent gases • No loss in sensitivity • Enhanced molecular ions and reduced fragmentation • No ionisation of carrier gas/background gases • Reduction of matrix impact Enhanced signal-to-noise and lower LoD for target analytes

Variable-energy ionisation Transition of fragmentation pattern aids structural elucidation 70 eV 16 eV 12 eV

Select-eV ionisation of alkanes Pentacosane (C25H52) 70 eV Molecular ion: 1.5% (800 counts) 14 eV Molecular ion: 26% (4000 counts)

The full presentation can be downloaded from the Markes website http://www.markes.com/Resources/Scientificpublications/Conference-presentations.aspx

Contact Markes enquiries@markes.com www.markes.com

Add a comment

Related presentations

Related pages

Select-eV launch at HTC-13 - Markes International ...

... at HTC-13, in Bruges, Belgium. This conference is a ... and Select-eV technology to enhance GC–MS ... Select-eV: Shaping the future of GC–MS
Read more

Conference presentations - Markes International - thermal ...

Conference posters; Conference presentations; ... (HTC-13, 2014) 3 Feb 2014 5.1 Mb Select-eV - Shaping the future of GC-MS (HTC-13, 2014)
Read more

Gc Ms | LinkedIn

View 71993 Gc Ms posts ... Ready to start 'nailing' GC/MS? Attention NIST 2014 Users!!Tenth Edition of ... Select-eV shaping the future of GC-MS (HTC-13, ...
Read more

Gc/ms | LinkedIn

Gc/ms at a glance: 71,763 LinkedIn members have this skill. What they are skilled at. HPLC (29,558 members) Chemistry (26,994 members) Analytical Chemistry ...
Read more

Markes International shapes the future of GC–MS by ...

Markes International shapes the future of GC–MS by ... a new variable-energy electron ionisation technology. ... at the HTC-13 conference ...
Read more

More documents for Schauenburg (Group) - Markes ...

Jefferies 2015 Global Healthcare Conference ... the Future of GC-MS by Launching a New ... source technology for GC-MS, Select-eV®. ...
Read more

Markes International Shapes the Future of GC-MS by ...

This makes Select-eV perfect for any GC–MS analyst ... in the GC–MS field for their ... at the HTC-13 conference in ...
Read more

Select-eV® ion source Markes International Ltd. - [MSC ...

Jefferies 2015 Global Healthcare Conference ... the Future of GC-MS by Launching a New ... source technology for GC-MS, Select-eV®. ...
Read more