Radiographic factor

100 %
0 %
Information about Radiographic factor
Education

Published on March 3, 2014

Author: saketjain543

Source: slideshare.net

Description

Radiographic factor

Dr Saket Jain

  Degree of blackening within the image Defined more accurately when type of image receptor is considered 1- Photographic film 2- Digital image capture

  1) 2) 3) Difference in density between structures of interest within the image . Built up in three main stages Subject contrast Radiographic contrast Subjective contrast

  1) 2) 3) 4) Feature of object (subject) under examination Factors that influence The region of body under examination Contrast media Pathology Kilo voltage

Is the difference in optical density on different parts of the processed film or differences in computer screen brightness and depends on 1) Subject contrast 2) Scattered radiation reaching the image receptor 3) Image acquisition device 4) Film fog 5) Exposure 6) Development 

The personal appreciation of the contrast in the image  Depends on 1) Radiographic contrast 2) The observer 3) Viewing condition 4) Computer screen / monitor 

  For a given FFD (focus to film distance) the greater the distance between the object and the film the greater will be the magnification of the image . image size FFD Magnification = = object size FOD FOD – focus to object distance

 Distorted image will be produced if not all parts of the image are magnified by the same amount .  Beam is right angle to object = distorted elongated image is produced  Beam is right angle to image receptor than the foreshortened image is produced

The aim is to produce an image that is as sharp as possible in order to resolve fine detail within the image  Important for looking subtle fractures  Factor lead to UNSHARPNESS 1) Geometry 2) Movement 3) Absorption 4) Photographic / acquistion factors 

 Degree increases by increased focal spot size and increased object to film distance object to film distance x focal spot size object to focus distance

 Sharpness can be increased by using a shorter exposure time (lower mAs with higher KVp , higher mA or greater tube loading time) by small object to film distance & immobilisation .

The choice of factors will depend on the region being examined .  Exposure factors to be selected are 1) The mAs 2) The kilovoltage 3) The FFD – focus to film distance 

    MA = tube current = number of electrons and quantity of x-rays produced Intensity X-ray tube current and exposure time (sec) Density is diectly related General rule – mA should be as high as possible with a short time , to reduce the risk of movement unsharpness

   KVP = Energy of x-rays = higher penetrability, it moves through tissue Density directly but not linearly related Contrast depends Halving or doubling mAs is equivalent to increasing or decreasing kVp by 10-15%

    X-ray tube not to be too closed Short FFD could give unacceptable geometric unsharpness FFD not to be excessive otherwise the large increase in mAs required would mean high tube loading Most radiographic examinations are carried out at 100 cms

Focus to Film distance : new dist 2 New mAs x original mAs old dist 2 

  Undesirable fluctuation in optical density of the image . If image acquisition device is used , then an insufficient mAs will manifest as noise or mottle .

 Radiographic variables Density Contrast Increase MAS Decrease MAS increase KVP decrease KVP increase FFD decrease FFD increase OID decrease OID no change no change decrease increase no change no change increase decrease increase decrease increase decrease decrease increase decrease increase

increase collimation decrease collimation decrease increase increase decrease

200 cm 150 cm 100 cm

GEOMETRIC MOVEMENT PHOTOGRAPHIC A Use fine focus, standardized(large) FFD Use short exposure time with high tube loading Use fine grained screens, single sided emulsion B Use small OFD , avoid equipment vibration Use small OFD ; Ensure all cassettes immobilization ; make maintain good film / patient comfortable ; give screen contact clear instructions to patient about keeping still OFD – object to film distance

Add a comment

Related presentations

Related pages

Prime Factors of Radiographic Exposure - Prezi

SUBJECT CONTRAST: Contrast significantly influenced by the tissue density within the patient. Changes in mA affect the rate of exposure (the number of ...
Read more

Radiology

Radiology Homepage; Managing your Account; RSNA ... 5-Year Impact Factor—the average number of times articles from the journal published in the past five ...
Read more

Factors affecting radiographic image Flashcards | Quizlet

For each question answer how increasing the factor affects density, contrast, sharpness, and distortion
Read more

Industrial radiography - Wikipedia

Before commencing a radiographic examination, ... Radiographic testing of the weld seam of automatic fusion arc welded steel tubes for the detection of ...
Read more

Risk Factors for Radiographic Progression of ...

Risk Factors for Radiographic Progression of ... Medial MAT compared with lateral MAT was also a significant risk factor ...
Read more

Radiographic factor - HubSlide

Radiographic factor. Toggle navigation. BUSINESS; EDUCATION; TECHNOLOGY; TRAVEL; MORE TOPICS; Sign up; Sign in; Home. Education. Radiographic factor. of 28 ...
Read more

The Selection of Patients for Dental Radiographic Examinations

THE SELECTION OF PATIENTS FOR DENTAL RADIOGRAPHIC EXAMINATIONS REVISED: 2004 AMERICAN DENTAL ASSOCIATION Council on Dental Benefit Programs
Read more

Factors Affecting Radiographic Quality - OoCities

Radiographic Quality A “diagnostic” radiograph is defined as one showing the tissues adequately penetrated, sharply outlined, and the variations in ...
Read more

Crucial Factor Affecting Film Radiography - ndt.net

ABSTRACT . The paper reviews the status of film radiography in the realm of modern industrial radiographic inspection techniques. Modern techniques have ...
Read more