Physical Security Lecture

50 %
50 %
Information about Physical Security Lecture
Education

Published on January 5, 2008

Author: Alien

Source: authorstream.com

PHYSICAL SECURITY (NSTISSI 4011):  PHYSICAL SECURITY (NSTISSI 4011) BY Josef Onuoha CS 996 Outline:  Outline Goals of Physical Security Perimeter and Building protection Access Controls Distributed Processing Stand-alone Systems and Peripherals Environment and Life Safety Controls Tamper Resistance Goals of Physical Security:  Goals of Physical Security Prevent unauthorized access to equipment, installations, material, and documents Safeguard against espionage, sabotage, damage, and theft Safeguard personnel Perimeter Protection:  Perimeter Protection Standoff distance The maintained distance between where a vehicle bomb is allowed and the target Exclusive Standoff Zone Vehicles are not allowed within perimeter unless they have been searched and cleared Nonexclusive Standoff Zone Established when a facility or location permits a mixture of trucks and cars. Includes inner and outer perimeters Perimeter Protection:  Perimeter Protection Perimeter Protection:  Perimeter Protection Speed Control Controls the speed of vehicles used for bombs Perimeter Protection:  Perimeter Protection Vehicle barriers Perimeter Protection:  Perimeter Protection Perimeters should also protect against Standoff weapons such as riffles, shot guns, pistols Primary defense is to obstruct Line Of Sight (LOS) from vantage point outside the site Use a Predetonation Screen Perimeter Protection:  Perimeter Protection Perimeter Protection:  Perimeter Protection Surveillance aggressors remain outside of controlled areas and try to gather information from within those areas Designers must eliminate or control vantage points from which aggressors can surveil or eavesdrop on assets or operations. Trees, bushes, fences, other buildings etc Perimeter Protection:  Perimeter Protection Perimeter Protection:  Perimeter Protection Lighting Discourage or deter attempts at entry by intruders. Prevent glare that may temporarily blind the guards. Different types Continuous, standby, movable Different applications Entrances, Parking areas, Critical areas Staffing Security Guards Patrols Dogs Building Protection:  Building Protection A Sensitive Compartmented Information Facility (SCIF) is an accredited area, room, group of rooms, buildings, or installation where Sensitive Compartmented Information (SCI) may be stored, used, discussed, and/or processed We now focus on construction requirements of a SCIF Building Protection:  Building Protection Vault Specifications Building Protection:  Building Protection Vault Specification (cont) minimum compressive strength of 3000 psi after 28 days of aging for class A 5/8-inch diameter steel rein- forcing bars laid 6 inches on centers In seismic areas, 6-inch or thicker RC will be used. Building Protection:  Building Protection Walls The walls will be of either reinforced concrete in excess of four inches thick or solid masonry (stone or brick) in excess of eight inches thick Floors The floor and ceiling selected for a Secure Area will be at least a four inch thickness of concrete Building Protection:  Building Protection Entrances A Secure Area will be equipped with a GSA Class 6 vault door Windows It is preferable that Secure Area be windowless . Accessible windows, where required, will be secured with bars, installed as specified in the requirements Building Protection:  Building Protection Barred Window Specifications for SCIF Type of Installation Type A: Requires a steel frame with steel bars welded on it to be bolted to the inside of the facility window frame Type B: Requires imbedding the ends of steel bars in the masonry window frame of the facility Type C: Requires a grillwork of steel bars to be imbedded in the masonry walls immediately adjacent to the facility window frame Building Protection:  Building Protection Sound Attenuation for SCIF The SCIF walls, windows, floor and ceiling, including all openings, should provide sufficient sound attenuation to preclude inadvertent disclosure of conversation Must meet the following SCT: Executive Suite       45+ Briefing Rooms 45+ Auditoriums 50+ Building Protection:  Building Protection Telephone Security for SCIF Telephone cables and wires which penetrate a facility's perimeter will enter the facility through one opening and be placed under control at the interior face of the perimeter The number of telephone instruments servicing a SCIF will be limited to those operationally necessary Interior Intrusion Detection Systems:  Interior Intrusion Detection Systems Structural vibration sensors Detects energy due to hammering, drilling, etc Point sensors Detects close proximity to an object. Passive ultrasonic sensors detect acoustical energy Volumetric Motion sensors Detects intruder motion within the interior of a protected volume Exterior Intrusion Detection Systems:  Exterior Intrusion Detection Systems Fence sensors Detects penetration generated by mechanical vibrations and stresses in fence fabric and posts LOS sensors generate a beam of energy and detect changes in the received energy that an intruder causes by penetrating the beam. Alarms:  Alarms Requirements perimeter doors will be equipped with high security balanced magnetic door switches. Vault doors will be equipped with heat detectors and balanced magnetic switches. The interior spaces not continually occupied by authorized personnel will be protected by motion detection alarms. vents and ducts over six inches will be alarmed. Windows less than 18 feet from ground level will be alarmed Alarms:  Alarms Types Motion alarm detectors Overt body motion walking through the protected areas at the rate of one step per second for four seconds, in areas protected by ultrasonic, microwave, and other motion detection devices Door Switches Actual opening of doors (or windows or other openings using door switches) which are protected by balanced magnetic door switches. Alarms:  Alarms Types (cont) Capacitance Alarms Attempts to push hands, arm, or legs through the protected area (air ducts or vents); to touch an item being protected (door, window, wall, etc.); or to move protected objects (security containers). Tamper Switches Removal of the covers for sensors, alarm control units, day/night switches, and end of the line supervision control units should cause an alarm regardless of the status of the overall system Physical Access Control:  Physical Access Control Designate restricted area: Facilitates enforcement Physical Access Control:  Physical Access Control Locks Preset Locks and Keys Typical door looks Programmable Locks Mechanical (Cipher Locks) Electronic (Keypad Systems): Digital Keyboard Number of Combinations Number of Digits in Code Frequency of Code Change Physical Access Control:  Physical Access Control Cards Photo-ID cards Wireless Proximity readers Magnetic Strip cards Smart Cards Often Require Use of PIN Number with Card Readers: Card Insertion, Card Swipe & Proximity Physical Access Control:  Physical Access Control DOD Smart Cards (Common Access Cards) Physical Access Control:  Physical Access Control Biometric Devices Fingerprint/Thumbprint Scan Retina Scan Hand Geometry Facial Recognition Voice Verification Problems Cost Speed Accuracy Physical Access Control:  Physical Access Control Typical verification times for entry-control devices Physical Access Control:  Physical Access Control Visitor identification and control Visitors, Cleaning teams, Civilians in work areas after normal work hours, Government contractors Personnel Position Sensitivity Designation Management Review of Access Lists Background Screening/Re-Screening Termination/Transfer Controls Disgruntled Employees Physical Access Control:  Physical Access Control Movement Control Escorts Two-person rule Distributed Computing:  Distributed Computing Threats To Confidentiality Sharing Computers Sharing Diskettes To Availability User Errors To Data Integrity Malicious Code Version Control Physical security of Distributed Computing:  Physical security of Distributed Computing Office Area Controls Entry Controls Office Lay-Out Property controls Electronic Media Controls Clean-Desk Policy Space protection devices Heat/Humidity considerations Stand-alone Systems and Peripherals:  Stand-alone Systems and Peripherals PC Physical Control Cable locks Vinyl-covered steel cable anchoring the PC or peripheral to desk Port controls Devices that secure data ports (such as USB ports) and prevent their use Stand-alone Systems and Peripherals:  Stand-alone Systems and Peripherals PC Physical Control (cont) Switch Controls A cover for the on/off switch, which prevents a user from switching off the file server’s power Peripheral switch controls Lockable switches that prevent a keyboard from being used Electronic Security Boards Boards inserted into an expansion slot in the PC and force a user to enter a password when the unit is booted Environment and Life safety Controls:  Environment and Life safety Controls Environment considerations to physical security include the following Electric Power RFI, EMI Implement TEMPEST Humidity Humidity of < 40% increases static elec. Damage potential Emergency power off controls Voltage monitoring/recording Surge protection Environment and Life safety Controls:  Environment and Life safety Controls Electric Power (cont) Backup power Backup feeders, UPS Emergency power generators Environment and Life safety Controls:  Environment and Life safety Controls Temperature Temperatures When Damage Occurs Paper Products: 350o Computer Equipment: 175o Disks: 150o Magnetic Media: 100o Fire detection Heat-sensing Flame-actuated Smoke-actuated Automatic dial-up fire alarm Environment and Life safety Controls:  Environment and Life safety Controls Fire Extinguishing Systems Wet pipe Dry pipe Deluge Suppression mediums Halon Excellent for vaults, equipment cabinets, etc Carbon IV Oxide Great for unattended facilities. Potentially dangerous Information System Centers:  Information System Centers Site selection Low visibility Low natural disaster threat Easy access to external services such as police, fire, hospitals, etc Information System Centers:  Information System Centers Infrastructure Servers, switches, routers, should be placed in looked racks and looked rooms Wiring and cables should be routed through walls, floors, etc to avoid tampering Uninterrupted power supply should exist for computing facility Tamper Resistance:  Tamper Resistance A device is said to be tamper-resistant if it is difficult to modify or subvert, even for an assailant who has physical access to the system. Specialized materials used to make tampering difficult One-way screws, epoxy encapsulation, trox Closely tied to tamper detection and response Tamper Detection:  Tamper Detection The ability of a device to sense that it is under physical attack and includes Switches to detect opening of device covers Sensors to detect changes in light or pressure within the device Barrier to detect drilling or penetration of physical boundary Paint Tamper Response:  Tamper Response Tamper Response is the counter measure taken upon the detection of tampering Ex.: Erase memory, shutdown/disable device, enable logging This is especially very important in the case of cryptographic keys stolen or lost This is especially very important in the case of cryptographic keys stolen or lost Computational errors introduced into a smart card can deduce the values of cryptographic keys hidden in the smart card layers of a chip can be uncovered by etching, discerning chip behavior by advanced infrared probing, and reverse-engineering chip logic OPSEC:  OPSEC Operations security (OPSEC) is an analytic process used to deny an adversary information - generally unclassified Trains people on the handling of information We can apply OPSEC in our daily lives “What could an adversary glean from the knowledge of this activity?” Resources:  Resources Physical Security Requirements For NSA/CSS Sensitive Compartmented Information Facilities FM 3-19.30 Physical Security, Department of the Army AR 380-5 Appendix H Classified document and Material Storage Smart Card/Common Access Card Program http://www.don-ebusiness.navsup.navy.mil/portal/page?_pageid=36,74750,48_72991&_dad=pebiz&_schema=PEBIZ

Add a comment

Related presentations

Related pages

Physical Security - University of Tennessee at Chattanooga

Physical Security “encompasses the design, implementation and maintenance of counter measures that protect the physical resources of an organization ...
Read more

Physical Security - Information Systems and Internet Security

Goals of Physical Security •Safeguard personnel •Prevent unauthorized access to facilities, data, or equipment •Safeguard against espionage, sabotage,
Read more

Physical_Security_Lecture - PHYSICAL SECURITY (NSTISSI ...

View Notes - Physical_Security_Lecture from COMP 6370 at Auburn. PHYSICAL SECURITY (NSTISSI 4011) BY Josef Onuoha CS 996 Outline Goals of Physical
Read more

Physical Security Lecture - Ace Recommendation Platform - 21

Interior Intrusion Detection Systems• Structural vibration sensors– Detects energy due to hammering, drilling, etc• Point sensors&ndash ...
Read more

Physical Security Lecture - Ace Recommendation Platform - 27

Physical Access Control• Locks– Preset Locks and Keys• Typical door looks– Programmable Locks• Mechanical (Cipher Locks)&bull ...
Read more

Checklist for Physical Security Risk Assessments

Checklist for Physical Security Risk Assessments ... Before conducting a physical security risk assessment, Stasiak has institutions answer these questions:
Read more

Physical Security - bank information security

Physical information security concerns the protection of data from non-electronic means such as physical attacks, thefts or loss.. bank information security
Read more

Lecture 21: Security introduction | Video Lectures ...

Video lecture on computer security, protection, security goals, the safety net approach, and cryptography.
Read more