UNRAVELLING FIBERS AND FIBER TO THE HOME A Project Report Submitted in partial fulfillment of requirement for the award of the degree of Bachelor of Technology Submitted By: Vanhishikha Bhargava (Roll No: 0941631056) Under the Supervision of Mr. Vinod C.P (Technical and Business Development Head) Advanced Fiber Systems Pvt. Ltd. No. 137/ 2, Service Road, Outer Ring Road Banaswadi, Kalyan Nagar Post Bangalore - 560043 Department of Electronics and Communication G.N.I.T. (Girls) GREATER NOIDA Session 2012-2013 1

INDEX Basics of Fiber Optics and its Evolution 01 Color Coating 05 Understanding wavelengths 06 Types of Optical Fibers 11 Advantages and Disadvantages of Optical Fibers 14 Applications of Optical Fibers 15 ITU- T Standards 16 Connectors and its Types 20 Polishing and its Types 27 Adapters and its Types 29 Attenuators and its Types 34 FTTH – Customer Premises 38 Cables and its Types 39 Losses in Optical Fibers 56 Splitters and its Types 66 Field Assembly Connectors 70 Splicing and its Types 72 Wavelength Division Multiplexing 75 Conclusion 77 Bibliography 78 2

DECLARATION I hereby declare that this project report entitled, ―Unravelling Fibers and Fiber To The Home‖, has been prepared by me during the academic year 2012-13, under the guidance and supervision of Mr.Vinod C.P (Technical and Business Development Head). I also declare that this project is the result of my own efforts and the information is collected from the company’s records and the conclusion is arrived after discussing with the project head and other staff. Date: 24-07- 2012 Place: Greater Noida Signature of the Candidate (Vanhishikha Bhargava) 3

ACKNOWLEDGEMENT I would like to express my deep sense of gratitude to the department of Electronics and Communication, Greater Noida Girls Institute of Technology, GautamBuddh Technical University, for giving an opportunity to do this training which helped me to understand the real working environment. First and for most, I would like to express my deep sense of gratitude to Mr. Shanbhag RV ( Technical Director) and Mr. Vijay Kumar HP (Business Development Director) , who have been a source of inspiration throughout my course their guidance and advice have made this work possible. I am very grateful to Mr. Vinod C.P (Technical and Business Development Head) for his advice and guidance throughout this project. I sincerely thank Mr. Anantha B.N, Mrs. Vimala S.V, and other employees for their co-operation, without them my study would not have been a success. I also wish to present my gratitude to my parents, and all my friends who have directly and indirectly helped to bring out this project report. VANHISHIKHA BHARGAVA 4

COMPANY PROFILE AFS is a Bangalore based original equipment manufacturer. We provide full range of passive products for network management. We manufacture, distribute and supply fiber optic products that telecom service providers require for high speed, scalable and reliable voice ,video and data services. AFS is expanding through its relentless efforts, aimed at providing true value to the wide segments of telecom and enterprise businesses all across the globe. Our Vision To be a leading manufacturer of full line fiber optic interconnect products and fiber management solutions for the telecommunication industry, as well as being an active contributor in the establishment of telecom infrastructure in the country. Our Mission To distinguish ourself as a customer driven company, providing genuine concern and competent products/services to our valued customers. We will also ensure total customer satisfaction. Production Team Backed by a strong drive for research and development, our production team is an amalgamation of technical expertise and proprietary technological expertise to provide the telecom service providers the best in Quality Technology Reliability and Design aesthetics. Our main strength is this team of highly motivated and qualified designers, researchers and engineers with a high level of knowledge and dedication. We believe in keeping close contact with world renowned academic institutions, other industry leaders and experts for understanding the evolving industry requirements. 5

AFS GREEN POLICY Our green policy is based on providing efficient and eco-friendly practices and products, which upon usage and disposal will have minimal impact on the environment. We are committed to apply the best green practices and strive to provide eco sustainability in all the activities we undertake. We are committed towards reducing our carbon footprint and improving out green credentials. Our GREEN COMMITMENT stands for – 1. Energy conservation. Use of energy efficient lighting (CFL) Use of public transportation or taking a walk instead of using a car Working with other green businesses 2. 3Rs’ – - Reduce Waste - Reduce material - Recycle waste By reducing waste we try to optimise the full use of a product in its life cycle. Use of digital and electronic and digital communication before using print or paper based communication. Thus, promoting a PAPERLESS office in the long run. By reusing paper, we ensure that our carbon footprint is minimised. All waste papers are disposed through recycling only and using them on both sides. For recycling, we work with NGOs to ensure that we have zero discharge to the landfill. 6

INTRODUCTION TO OPTICAL FIBRES ORIGIN OF OPTICAL FIBRES Optical communication systems date back two centuries, to the ―OPTICAL TELEGRAPH" invented by French engineer Claude Chappe in the 1790s. His system was a series of semaphores mounted on towers, where human operators relayed messages from one tower to the next. It beat hand-carried messages hands down, but by the mid 19th century, it was replaced by the electric telegraph, leaving a scattering of ―telegraph hills‖ as its most visible legacy. In the 1840s, physicist Daniel Collodo and Jacques Babinet showed that light could be directed along jets of water for fountain displays. In 1854, John Tyndall, a British physicist, demonstrated that light could travel through a curved stream of water thereby proving that a light signal could be bent. He proved this by setting up a tank. He proved this by setting up a tank of water with a pipe that ran out of one side. As water flowed from the pipe, he shone a light into the tank into the stream of water. As the water fell, an arc of light followed the water down. Alexander Graham Bell patented an optical telephone system, which he called PHOTOPHONE, in 1880, but his earlier invention, the telephone , proved far more practical. He dreamed of sending signals through air, but the atmosphere did not transmit light as reliably as wires carried electricity. In the intervening years, new technology that would ultimately solve the problem of optical transmission slowly took root, although it was a long time before it was adapted for communications. This technology depended on the phenomenon of TOTAL INTERNAL REFLECTION, which can confine light in a material surrounded by other material with lower refractive index such as glass and air .Optical fibers went a step further. They are essentially transparent rod glass or plastic stretched to be long and flexible. 7

BASICS OF OPTICAL FIBRES Optical fiber is a medium in which communication signals are transmitted from one location to another in the form of light through thin fibers of glass or plastic. These signals are digital pulses or continuously modulated analog streams of light representing information. These can be voice information, data information, computer information, video information or any other type of information. This same type of information can be sent on metallic wires such as twisted pair and coax (coaxial cables) and through the air on microwave frequencies. Total Internal Reflection Total internal reflection is an optical phenomenon that happens when a ray of light strikes a medium boundary at an angle larger than a particular critical angle with respect to the normal to the surface. If the refractive index is lower on the other side of the boundary and the incident angle is greater than the critical angle, no light can pass through and all of the light is reflected. The critical angle is the angle of incidence above which the total internal reflection occurs. When light crosses a boundary between materials with different kinds of refractive indices, the light beam will be partially refracted at the boundary surface, and partially reflected. However, if the angle of incidence is greater (i.e. the ray is closer to being parallel to the boundary) than the critical angle – the angle of incidence at which light is refracted such that it travels along the boundary – then the light will stop crossing the boundary altogether and instead be totally reflected back internally. This can only occur where light travels from a medium with a higher [n1=higher refractive index] to one with a lower refractive index [n2=lower refractive index]. For example, it will occur when passing from glass to air, but not when passing from air to glass. If you have ever half-submerged a straight stick into water, you have probably noticed that the stick appears bent at the point it enters the water. This optical effect is due to refraction. As light passes from one transparent medium to another, it changes speed, and bends.Each medium has a different refractive index. The angle between the light ray and the normal as it leaves a medium is called the angle of incidence. The angle between the light ray and the normal as it enters a medium is called the angle of refraction. 8

Snell’s Law Snell's law(law of refraction) is a formula used to describe the relationship between the angles of incidence and refraction, when referring to light or other waves passing through a boundary between two different isotropicmedia, such as water and glass. Refraction of light occurs at the interface between two media of different refractive indices, with n2> n1. Since the velocity is lower in the second medium (v2< v1), the angle of refraction θ2 is less than the angle of incidence θ1; that is, the ray in the higher-index medium is closer to the normal.In optics, the law is used in ray tracing to compute the angles of incidence or refraction. Snell's law states that the ratio of the sines of the angles of incidence and refraction is equivalent to the ratio of phase velocities in the two media, or equivalent to the opposite ratio of the indices of refraction: With each as the angle measured from the normal, as the velocity of light in the respective medium (SI units are meters per second, or m/s) and as the refractive index (which is unit less) of the respective medium. 9

Numerical Aperture Fibers are labeled by their numerical apertures. The numerical aperture takes into account not only the cone of acceptance, but the effect on that cone of different media outside the fiber. We can find the cut-off angle θ0max by working backward from the point where light strikes the upper edge of the fiber. In order for total internal reflection (TIR) to occur, the angle at this edge must be greater than the critical angle: θ1>θc θ'1 is defined as the angle the light makes with respect to the normal at the entrance (left side) of the fiber. Looking at the figure, we see that θ'1 and θ1 are complementary. Thus θ'1< 90 - θc. Snell's law applies at the entrance to the fiber, so n0 sin θ0 = n1 sin θ1<n1 sin (90 - θc) n0 sin θ0max = (n12 - n22)1/2 = NA Rayleigh Scattering Rayleigh scattering, named after the British physicist Lord Rayleigh, is the elastic scattering of light or other electromagnetic radiation by particles much smaller than the wavelength of the light. The particles may be individual atoms or molecules. It can occur when light travels through transparent solids and liquids, but is most prominently seen in gases. Rayleigh scattering is a function of the electric polarizability of the particles. Rayleigh scattering is an important component of the scattering of optical signals in optical fibers. Silica fibers are disordered materials, thus their density varies, on a microscopic scale. The density fluctuations give rise to energy loss due to the scattered light, with the following coefficient wheren is the refraction index, is the photo elastic coefficient of the glass, is Boltzmann constant, and is the isothermal compressibility. Tf is a fictive temperature, representing the temperature at which the density fluctuations are "frozen" in the material. 10

Fresnel’s Reflection When light moves from a medium of a given refractive indexn1 into a second medium with refractive index n2, both reflection and refraction of the light may occur. The Fresnel equations describe what fraction of the light is reflected and what fraction is refracted (i.e., transmitted). They also describe the phase shift of the reflected light. The relationship between these angles is given by the law of reflection: andSnell's law: The fraction of the incident power that is reflected from the interface is given by the reflectanceR and the fraction that is refracted is given by the transmittanceT. The media are assumed to be nonmagnetic. 11

COLOR COATING USING EIA-TIA STANDARDS Each fiber is distinguishable by means of color-coding in accordance with TIA/EIA-598A, ―Optical Fiber Cable Color Coding". All fibers and buffer tubes are color coded to facilitate individual fiber identification. The individual fiber colors used in loose tube cable are given in the following table: TUBE COLOR 1 BLUE (BL) 2 ORANGE (OR) 3 GREEN (GR) 4 BROWN (BR) 5 SLATE (SL) 6 7 WHITE (WH) RED (RD) 8 BLACK 9 YELLOW (BK) (YW) 10 VIOLET(VI) 11 ROSE(RS) 12 AQUA (AQ) 12

Understanding Wavelengths in Fiber Optics Fiber optics is full of jargon but it's important to understand it. One of the more confusing terms to many is "wavelength." It sounds very scientific, but it is simply the term used to define what we think of as the color of light. Light is part of the "electromagnetic spectrum" that also includes x-rays, ultraviolet radiation, microwaves, radio, TV, cell phones, and all the other wireless signals. They are simply electromagnetic radiation of different wavelengths. We refer to the range of wavelengths of electromagnetic radiation as a spectrum. Wavelength and frequency are related, so some radiation is identified by its wavelength while others are referred to by their frequency. For the radiation of shorter wavelengths, light, UV and x-rays, for example, we generally refer to their wavelength to identify them, while the longer wavelengths like radio, TV and microwaves, we refer to by their frequency. For fiber optics with glass fibers, we use light in the infrared region which has wavelengths longer than visible light, typically around 850, 1300 and 1550 nm. The attenuation of glass optical fiber is caused by two factors, absorption and scattering. Absorption occurs in several specific wavelengths called water bands due to the absorption by minute amounts of water vapor in the glass. Scattering is caused by light bouncing off atoms or molecules in the glass. It is strongly a function of wavelength, with longer wavelengths having much lower scattering. Have you ever wondered why the sky is blue? It's because the light from the sun is more strongly scattered in the blue. Fiber optic transmission wavelengths are determined by two factors: longer wavelengths in the infrared for lower loss in the glass fiber and at wavelengths which are between the absorption bands. Thus the normal wavelengths are 850, 1300 and 1550 nm. Fortunately, we are also able to make transmitters (lasers or LEDs) and receivers (photo detectors) at these particular wavelengths. If the attenuation of the fiber is less at longer wavelengths, why don't we use even longer wavelengths? The infrared wavelengths transition between light and heat, like you can see the dull red 13

glow of an electric heating element and feel the heat. At longer wavelengths, ambient temperature becomes background noise, disturbing signals. And there are significant water bands in the infrared. Plastic optical fiber (POF) is made from materials that have lower absorption at shorter wavelengths, so red light at 650 nm is commonly used with POF, but at 850 nm attenuation is still acceptable so short wavelength glass fiber transmitters may be used. The three prime wavelengths for fiber optics, 850, 1300 and 1550 nm drive everything we design or test. NIST (the US National Institute of Standards and Technology) provides power meter calibration at these three wavelengths for fiber optics. Multimode fiber is designed to operate at 850 and 1300 nm, while singlemode fiber is optimized for 1310 and 1550 nm. The difference between 1300 nm and 1310 nm is simply a matter of convention, harking back to the days when AT&T dictated most fiber optic jargon. Lasers at 1310 nm and LEDs at 1300 nm were used in singlemode and multimode fiber respectively. Plastic Optical Fiber (POF) Multimode Graded Index Fiber Singlemode Fiber 650 nm 850 nm 850 nm 1300 nm 1310 nm 1490 - 1625 nm OPTICAL WAVELENGTHS AND SPECTRUM Band O- band E- band S- band C- band L- band U- band Wavelength range 1260 nm- 1360 nm 1360 nm- 1460 nm 1460nm- 1530 nm 1530 nm- 1565 nm 1565 nm- 1625 nm 1625 nm – 1675 nm Description Original band Extended band Short wavelength band Conventional band Long wavelength band Ultra long wavelength band . 14

CONSTRUCTION An optical fiber consists of a light carrying core surrounded by a cladding that traps the light in the core by the principle of TOTAL INTERNAL REFLECTION. DIAGRAM Core: The core of a conventional optical fiber is a cylinder of glass or plastic that runs along the fiber's length. The core is surrounded by a medium with a lower index of refraction, typically a cladding of a different glass, or plastic. Light travelling in the core reflects from the core-cladding boundary due to total internal reflection, as long as the angle between the light and the boundary is less than the critical angle. As a result, the fiber transmits all rays that enter the fiber with a sufficiently small angle to the fiber's axis. The limiting angle is called the acceptance angle, and the rays that are confined by the core/cladding boundary are called guided rays. The core is characterized by its diameter or cross-sectional area. In most cases the core's cross-section should be circular, but the diameter is more rigorously defined as the average of the diameters of the smallest circle that can be circumscribed about the core-cladding boundary, and the largest circle that can be inscribed within the core-cladding boundary. 15

Cladding: Cladding is one or more layers of material of lower refractive index, in intimate contact with a core material of higher refractive index. The cladding causes light to be confined to the core of the fiber by total internal reflection at the boundary between the two.[1] Light propagation in the cladding is suppressed in typical fiber. Some fibers can support cladding modes in which light propagates in the cladding as well as the core. (From Federal Standard 1037C and from MIL-STD-188) The numerical aperture of a fiber is a function of the indices of refraction of the cladding and the core by: Buffer coating: In a fiber optic cable, a buffer is one type of component used to encapsulate one or more optical fibers for the purpose of providing such functions as mechanical isolation, protection from physical damage and fiber identification. The buffer may take the form of a miniature conduit, contained within the cable and called a "loose buffer", or "loose buffer tube". A loose buffer may contain more than one fiber, and sometimes contains a lubricating gel. A "tight buffer" consists of a polymer coating in intimate contact with the primary coating applied to the fiber during manufacture. Buffer application methods include spraying, dipping, extrusion and electrostatic methods. Materials used to create buffers can include fluoropolymers such as polyvinylidene fluoride (Kynar), polytetrafluoroethylene (Teflon), or polyurethane. 16

TYPES OF OPTICAL FIBRES OPTICAL FIBERS SINGLEMODE FIBERS MULTIMODE FIBERS STEP INDEX GRADED INDEX OM1/OM2/OM3 STEP INDEX SINGLEMODE FIBERS: Single Mode cable is a single stand (most applications use 2 fibers) of glass fiber with a diameter of 8.3 to 10 microns that has one mode of transmission. Single Mode Fiber with a relatively narrow diameter, through which only one mode will propagate typically 1310 or 1550nm. Carries higher bandwidth than multimode fiber, but requires a light source with a narrow spectral width. Figure: Single Mode Step Index Fiber 17

MULTIMODE FIBRES: Multi-Mode cable has a little bit bigger diameter, with a common diameters in the 50-to-100 micron range for the light carry component (in the US the most common size is 62.5um). Most applications in which Multi-mode fiber is used, 2 fibers are used (WDM is not normally used on multi-mode fiber). Step Index Multimode Fiber This diagram corresponds to multimode propagation with a refractive index profile that is called step index. The diameter of the core is fairly large relative to the cladding. There is also a sharp discontinuity in the index of refraction as you go from core to cladding. As a result, when light enters the fiber-optic cable on the left, it propagates down toward the right in multiple rays or multiple modes. This yields the designation multimode. As indicated, the lowest-order mode travels straight down the center. It travels along the cylindrical axis of the core. Figure: Multimode Step Index 18

Graded Index Multimode Fiber Multimode graded index fiber has a higher refractive index in the core that gradually reduces as it extends from the cylindrical axis outward. Here the variation of the index of refraction is gradual as it extends out from the axis of the core through the core to the cladding. There is no sharp discontinuity in the indices ofrefraction between core and cladding. The core here is much larger than in the single-mode step index. Figure: Graded Index Multimode Fiber Multi-mode fibers are described by their core and cladding diameters. The transition between the core and cladding can be sharp, which is called a step index profile, or a gradual transition, which is called a graded index profile. The two types have different dispersion characteristics and thus different effective propagation distance. In addition, multi-mode fibers are described using a system of classification determined by the ISO 11801 standard — OM1, OM2, and OM3 — which is based on the modal bandwidth of the multimode fiber. For many years 62.5/125 µm (OM1) and conventional 50/125 µm multi-mode fiber (OM2) were widely deployed in premises applications. These fibers easily support applications ranging from Ethernet (10 Mbit/s) to Gigabit Ethernet (1 Gbit/s) and, because of their relatively large core size, were ideal for use with LED transmitters. Newer deployments often use laser-optimized 50/125 µm multi-mode fiber (OM3). Fibers that meet this designation provide sufficient bandwidth to support 10 Gigabit Ethernet up to 300 meters. Optical fiber manufacturers have greatly refined their manufacturing process since that standard was issued and cables can be made that support 10 Gbit up to 550 meters. Laser optimized multi-mode fiber (LOMMF) is designed for use with 850 nm VCSELs. The migration to LOMMF/OM3 has occurred as users upgrade to higher speed networks. LEDs have a maximum modulation rate of 622 Mbit/s because they can not be turned on/off fast enough to support higher bandwidth applications. VCSELs are capable of modulation over 10 Gbit/s and are used in many high speed networks. OM4 (defined in TIA-492-AAAD) was finalized in August 2009,] and was published by the end of 2009 by the TIA. OM4 cable will support 125m links at 40 and 100 Gbit/s. Cables can sometimes be distinguished by jacket color: for 62.5/125 µm (OM1) and 50/125 µm (OM2), orange jackets are recommended, while Aqua is recommended for 50/125 µm "laser optimized" OM3 and OM4 fiber. 19

ADVANTAGES OF OPTICAL FIBRES Wide bandwidth- Optical carriers are superior to radio frequency and microwave carriers due to their high frequencies. Amount of data flow achieved through copper wires is limited. The very high frequency of operation in an optical fiber leads to very high rates of data transmission. Light weight and small size-Due to their small volume and lower density, optical fiber cables enjoy considerable weight advantages over typical copper co- axial cables. Immunity to electromagnetic interference-Since optical fibers are non conducting, they will neither generate nor receive electromagnetic interference. This feature allows the use of fibers in regions of high electric field. Lack of EMI cross talk between channels-Electromagnetic interference called cross talk occurs when two or more conducting lines lie near enough to each other to allow the signal from one to leak into the other because of electromagnetic fields. However, the electromagnetic fields extending from an optical fiber are negligible; hence there is no cross talk in an optical fiber. Lack of sparking-For special purpose applications that require transmission on information through hazardous cargo areas, fibers offer the potential advantage of not sparking, if there is a break in the transmission line. Compatibility with solid state sources- The physical dimensions of the fiber optic sources, detectors and connectors and the fiber itself are compatible with modern miniaturized electronics. Low cost-Copper is a critical commodity in the market and is hence, subjected to fluctuations in the prices. The primary ingredient of silica based fiber is widely available and is not a critical commodity. Not only does optical fiber offer enormous bandwidth, but it takes a lot less room. Any one of these copper bundles can be replaced with one fiber strand. No Emission Licenses-Fiber optics is a non- radiating means of information transfer and hence, no government license is required to use the optical spectrum. DISADVANTAGES OF OPTICAL FIBRES High investment cost. Need for more expensive optical transmitters and receivers. More difficult and expensive to splicethan wires. At higher optical powers, is susceptible to "fiber fuse" wherein a bit too much light meeting with an imperfection can destroy as much as 1.5 kilometers of wire at several meters per second. A "Fiber fuse" protection device at the transmitter can break the circuit to prevent damage, if the extreme conditions for this are deemed possible. Cannot carry electrical power to operate terminal devices. However, current telecommunication trends greatly reduce this concern: availability of cell phones and wireless PDAs; the routine inclusion of back-up batteries in communication devices; lack of real interest in hybrid metalfiber cables; and increased use of fiber-based intermediate systems. 20

APPLICATIONS OF OPTICAL FIBRES The use and demand for optical fiber has grown tremendously and optical-fiber applications are numerous. Telecommunication applications are widespread, ranging from global networks to desktop computers. These involve the transmission of voice, data, or video over distances of less than a meter to hundreds of kilometers, using one of a few standard fiber designs in one of several cable designs. Carriers use optical fiber to carry plain old telephone service (POTS) across their nationwide networks. Local exchange carriers (LECs) use fiber to carry this same service between central office switches at local levels, and sometimes as far as the neighborhood or individual home (fiber to the home [FTTH]). Optical fiber is also used extensively for transmission of data. Multinational firms need secureand reliable systems to transfer data and financial information between buildings to the desktop terminals or computers and to transfer data around the world. Cable television companies also use fiber for delivery of digital video and data services. The high bandwidth provided by fiber makes it the perfect choice for transmitting broadband signals, such as high-definition television (HDTV) telecasts. Intelligent transportation systems, such as smart highways with intelligent traffic lights, automated tollbooths, and changeable message signs, also use fiber-optic-based telemetry systems. Another important application for optical fiber is the biomedical industry. Fiber-optic systems are used in most modern telemedicine devices for transmission of digital diagnostic images. Other applications for optical fiber include space, military, automotive, and the industrial sector. 21

ITU-T STANDARDS Worldwide, technologies for broadband access networks are advancing rapidly. Among these, the technology applying single mode fiber provides for a high-capacity transmission medium which can answer the growing demand for broadband services. The experience with the installation and operation of single mode fiber and cable based networks is huge, and ITU-T Recommendation G.652 describing its characteristics has been adapted to this experience. Nevertheless, the specific use in an optical access network puts different demands on the fiber and cable which impacts its optimal performance characteristics. Differences with respect to the use in the general transport network are mainly due to the high density network of distribution and drop-cables in the access network. The limited space and the many manipulations ask for operator friendly fiber performance and low bending sensitivity. In addition, the cabling in the crowded telecom offices where space is a limiting factor has to be improved accordingly. TYPESOFITU-TSTANDARDS There are mainly three types of ITU-T Standards. These are discussed as follows: ITU-T G.652 ITU-T G.657 ITU-T G.655 22

ITU-T G652 Series G: Transmission Systems and Media, Digital Systems and Networks Transmission media characteristics. Recommendations ITU-T G652 describes the geometrical, mechanical and transmission attributes of a single-mode optical fiber and cable which has zero-dispersion wavelength around 1310 nm. This fiber was originally optimized for use in the 1310-nm wavelength region, but also be used at1490 and 1550 nm as well as other wavelengths. The first G.652 specification was created in 1984 with many revisions since. WAVELENGTH RANGE:1310 nm to 1550 nm The standards include the following: Mode field diameter (MFD) Cladding diameter Core-concentricity error Non-circulatory Cut-off wavelengths Macrobending losses Material properties of coefficient Refractive index profile Longitudinal uniformity of chromatic dispersion Chromatic dispersion coefficient TYPES NAME WAVELENGHTH RANGE ITU-T G.652B ITU-T G.652D 1360 nm to 1550 nm BIT RATE APPLICATIONS Supports up to STM-64 (OC-192) Supports up to STM-64 (OC-192) 23

ITU-T G657 The recommendation describes two categories of single mode optical fiber cable suitable for use in the access network, inside buildings at the end of those networks. The G.657 recommendation was created to support this optimization by recommending much improved bending performance compared with existing G.652 single mode fibers and cables. This is done by introducing two classes of single mode fibers, one of which, class a, is fully compliant with the G.652 single mode fibers and can also be used in other parts of the network.It is suitable for use in O, E, S, C and L bands. WAVELENGTH RANGE:1260nm to 1625nm The standards include the following: Mode field diameter (MFD) Cladding diameter Core-concentricity error Non-circulatory Cut-off wavelengths Macro bending losses Material properties of coefficient Refractive index profile Longitudinal uniformity of chromatic dispersion Chromatic dispersion coefficient TYPES NAME WAVELENGTH SPECIFICATIONS 1550 nm 1625 nm Minimum bend radius of 10mm Minimum design radius of 7.5mm Minimum bend radius of 7.5mm Minimum design radius of 5mm G.657A1 G.657A2 G.657B2 G.657B3 24

ITU-T G655 Recommendation of ITU-T G655 describes the geometrical , mechanical and transmission attributes of a single mode optical fiber which has a absolute value of chromatic dispersion coefficient greater than zero throughout the wavelength range .This dispersion reduces the growth of non-linear effects ,which are particularly deleterious in dense wavelength division multiplexing systems(DWDM). WAVELENGTH RANGE: 1530 nm to 1565 nm The standards include the following: Mode field diameter (MFD) Cladding diameter Core-concentricity error Non-circulatory Cut-off wavelengths Macro bending losses Material properties of coefficient Refractive index profile Longitudinal uniformity of chromatic dispersion Chromatic dispersion coefficient TYPES NAME ITU-T G.655A ITU-T G.655B SPECIFICATION Maximum launch power could be restricted Typical minimum channel spacing could be restricted to 200 GHz Maximum launch power could be higher than G.655A Typical minimum channel spacing could be restricted to 100 GHz or less 25

CONNECTORS An optical fiber connector terminates the end of an optical fiber, and enables quicker connection and disconnection than splicing. The connectors mechanically couple and align the cores of fibers so that light can pass. Better connectors lose very little light due to reflection or misalignment of the fibers. Optical fiber connectors are used to join optical fibers where a connect/disconnect capability is required. The basic connector unit is a connector assembly. A connector assembly consists of an adapter and two connector plugs. Due to the polishing and tuning procedures that may be incorporated into optical connector manufacturing, connectors are generally assembled onto optical fiber in a supplier’s manufacturing facility. Outside plant applications may involve locating connectors underground in subsurface enclosures that may be subject to flooding, on outdoor walls, or on utility poles. The closures that enclose them may be hermetic, or may be free-breathing. Hermetic closures will subject the connectors within to temperature swings but not to humidity variations unless they are breached. Free-breathing closures will subject them to temperature and humidity swings, and possibly to condensation and biological action from airborne bacteria, insects, etc. Connectors in the underground plant may be subjected to groundwater immersion if the closures containing them are breached or improperly assembled. Features of a good connector design: Low Insertion Loss Low Return Loss Ease of installation Low cost Reliability Low environmental sensitivity Ease of use FERRULES Ferrule is the most important component of fiber optic connectors. It could be made of different materials, such as plastics, stainless steel, and ceramics. Most of the ferrules used in optical connectors are made of ceramic material due to some of the desirable properties they possess. These include low insertion loss required for optical transmission, remarkable strength, small elasticity coefficient, easy control of product characteristics, and strong resistance to changes in environmental conditions. The production process is an extremely complex one, which begins with injecting zirconium-dioxide powder into pre-designed molds. The work-in-process is degreased, burned, reduced and ground, and then to become finished ceramic ferrules. Figure of a ferrule is given below: 26

TYPES OF CONNECTORS Many types of optical connector have been developed at different times, and for different purposes. Many of them are summarized in the table below: Short name Long form Coupling type Snap SC Subscriber Connector FC Ferrule connector Screw LC Lucent connector Snap ST Straight Tip Ferrule diameter 2.5 mm 2.5 mm Standard IEC 61754-4 Datacom and telecom; GBIC; extremely common IEC 6175413 Datacom, telecom, measurement equipment, single-mode lasers; High-density connections, SFP transceivers, XFP transceivers Multimode, rarely singlemode; APC not possible (note 3) Telecom, DWDM systems; 1.25 mm IEC 6175420 Bayonet 2.5 mm IEC 61754-2 E-2000 Snap, with light and dust-cap 2.5 mm IEC 6175415 BICONICAL Screw Snap (multiplex push-pull coupling) 2.5 mm MPO MultipleFiber PushOn/Pulloff MTRJ Mechanical Transfer Registered Jack FSMA Snap (duplex) Screw Typical applications Obsolete 2.5×6.4 mm IEC-617547; EIA/TIA604-5 (FOCIS 5) 2.45×4.4 mm IEC 6175418 3.175 mm IEC 60874-2 SM or MM multi-fiber ribbon. Same ferrule as MT, but more easily reconnect able. Used for indoor cabling and device interconnections. MTP is a brand name for an improved connector, which intermates with MPO. Duplex multimode connections Datacom, telecom, test and measurement 27

E2000CONNECTOR Features: The ferrule is protected by the integrated spring loaded shutter. The connector housing protects the ferrule all round against dust, dirt and scratches. Latched push – pull locking type.. Fiber cable assemblies result in super performance on insertion loss as well as exceptional repeatability. Full ceramic ferrule. Adjustable in 60˚ steps. Excellent for high packing density. Specifications: E2000 connector Specifications Single mode Multimode <0.20dB <0.25dB Insertion Loss Return Loss >55 dB (PC) >65 dB (APC) Durability <0.20 dB typical change, 1000 matings SC CONNECTOR SC optical fiber connector is comprised of a polymer body and aceramic ferrule plus a crimp over sleeve and rubber boot. These connectors are suitable for, 900μm and 2 and 3mm cables. Features: Threaded, key oriented coupling mechanism which allows repeatable, low loss connections. Simplex or duplex and multi fiber assemblies are available in both standard and custom configurations. Specifications: SC connector Specifications Single mode Insertion Loss Return Loss Durability Multimode <0.20dB <0.20dB >55dB >45dB 1000 mate/ demate cycles 28

FC CONNECTOR Both singlemode and multimode configurations come with a zirconia ceramic ferrule with pre- polished FC profile and convex spherical end. These end face types allow faster polishing, low back reflection and optical los, while ensuring maximum repeatability. Features: Precision mechanical dimension. Ultra low back reflection. Corrosion resistant body. For 3.0mm, 2.0mm jacket or 900 m buffer. Compatible with APC hardware. Free-floating APC ceramic ferrule. Specifications: FC connector Specifications Single mode Multimode <0.20dB <0.20dB >55dB >45dB Insertion Loss Return Loss Durability 1000 mate/ demate cycles ST CONNECTOR ST stands for Straight Tip connectors. They are used for both short distance and long line systems. It has a bayonet mount and a long cylindrical ferrule to hold the fiber. Because they are spring loaded, they have to be seated properly. Features: Twist lock bayonet coupling mechanism which ensures quick, highly repeatable, low loss connections. Standard crimp kevlar retention. Specifications: ST connector Specifications Single mode Insertion Loss Return Loss Durability Multimode <0.20dB <0.20dB >55dB >45dB 1000 mate/ demate cycles 29

LC CONNECTORS The LC Connector family was designed to provide a high performance SFFC incorporating traditional technology, advances in latching systems, and versatile for both singlemode and multimode fiber applications. Features: Available in 2mm patch, 3mmpatch and 900 μm. Termination Procedures: Prep cable end, Epoxy-Crimp-Polish. Connector versions available for: 2mm Cable, 900 μm Buffered Fiber, Simplex & Duplex. Available in Blue (single mode), Beige (multimode). Specifications: LC connector Specifications Single mode Insertion Loss Return Loss Multimode <0.20dB <0.20dB >50dB >45dB Durability 1000 mate/ demate cycles MT- RJ CONNECTORS MT-RJ Connector uses a RJ-latching mechanism familiar to installers. Also, the MT-RJ is a small formfactor connector package that doubles the densitycompared to standard SC connectors. Features: Precision molded MT ferrule. High precision guide pins for exact alignment. Duplex ferrule. Plug jack (RJ - 45) design. Specifications: MT-RJ connector Specifications Single mode Insertion Loss Return Loss Durability Multimode <0.20dB <0.25dB >45dB 1000 mate/ demate cycles 30

MPO CONNECTORS They are very high density, small form factor fiber optic connectors developed by NTT around the MT ferrule, to simply the process of pretermination. Features: No of Standard MT interface connects: 4, 8, and 12 singlemode or multimode fiber. Precision guide pins provide high-precision alignment for high-optical performance. Integral no-epoxy strain relief. Specifications: MPO connector Specifications Single mode Multimode <0.35db – premium <1.00dB- maximum <0.75dB >60dB >35dB 200 mate/demate cycles 200 mate/demate cycles Insertion Loss Return Loss Durability BICONIC CONNECTORS Biconic connector is still in use today; mostly for military applications. Biconic connector utilizes a screw type, spring loaded connection and features a cone-shaped polymer ferrule that helps to align the optical fibers at the connection interface. It provides top performance for singlemode and multimode applications. Features: Precision molded polymer. Conical thermoplastic ferrule. Singlemode / Multimode. Easy termination. Specifications: Specifications Singlemode/ Multimode Insertion loss ≤ 0.50dB typical Material - Body Precision molded 31

FSMA CONNECTORS SMA (Sub-Miniature Version-A)connectorsare coaxial RF connectors developed in the 1960s as a minimal connector interface for coaxial cable with a screw type coupling mechanism. The connector has a 50Ωimpedance. It offers excellent electrical performance from DC to 17 GHz. Features: Threaded nut connector. One piece construction. Simple termination. Single crimp design. Non- contact connector. Specifications: 128μm & 144μm SMA ferrule (zirconia, 905 series): < 0.8dB typical Insertion loss 128μm & 144μm stainless steel ferrule: < 2.0dB typical < 2.0dB typical FDDI CONNECTORS Features: Installation in push and pull style. Compatible with all FDDI-compliant connectors and active equipment. Low insertion loss. Clear indication of proper keying to end-users by connector labels. Various brand name connectors are available upon request. Specifications: Parameter Insertion loss Back reflection Durability Operating Temperature Singlemode 0.3Db 30Db 500 mate/ demate cycles -40°C to +80°C 32

POLISHING Fiber optic connectors can have several different ferrule shapes or finishes, usually referred to as polishes. Early connectors, because they did not have the keyed ferrules and could not rotate in mating adapters, always had an air gap between the connectors to prevent them from rotating and grinding scratches into the ends of the fibers. Beginning with the ST and FC, which had keyed ferrules, the connectors were designed to contact tightly, what we now call physical contact (PC) connectors. The end of the connector ferrule provides the optical contact between two fibers. We usually polish the ends to minimize the losses. 33

TYPES OF POLISHING The amount of insertion loss is affected by fiber alignment, and/or the quality of the finishing on the end of ferrule, while return loss is affected by the style of polishing on the ceramic ferrule in a connector. There are three different styles of polishing, reflected by their shape of the finish: 1. Physical Contact (PC) In the PC style, the fiber is polished to a smooth curve. As the name implies (i.e. physical contact), the ferrules of adjoining fibers come into physical contact. This reduces the air gap between the contacting ferrules, resulting in lower insertion losses. The smooth curve in the PC style is designed to reduce the return loss by reflecting the light out of the fiber. 2. Ultra Physical Contact (UPC) The UPC style ferrule has the shape of the PC style. They are polished with several grades of polishing film that allows for an ultra smooth surface. The main difference between UPC and PC is that the former have a lower return loss. 3. Angled Physical Contact (APC) The APC style produces the lowest return loss when compared to other styles. The ferrule is finished to anangle of typically 8 degrees. The angle is calculated so that it is less than the critical angle, which implies that light is not propagated back along the fiber. 34

ADAPTERS Fiber optic adapter are used in fiber optic connection, the typical use is to provide a cable to cable fiber connection. People sometimes also name them to be mating sleeves and hybrid adaptors, mating sleeves means this fiber optic adapter is used to connect the same type fiber optic connectors, while hybrid adaptors are the fiber optic adaptor types used to connect different kinds of fiber optic connectors. SC ADAPTER Typical SC fiber optic adapters are with plastic housing and for single mode SC UPC it is blue color, single mode SC APC it is green color, multimode SC UPC is beige color. Most of these adapters come with ceramic sleeves, while there are bronze sleeve SC adapters which are generally multimode types. SC Fiber optic adapter features: Compact design. High precision alignment. Low insertion and return loss and back reflection. Choice of metal or plastic housing, mount styles & flange options. SC Fiber optic adapter applications: CATV Telecommunication networks Local Area Networks (LANs) Data processing networks Industrial, military and medical ST ADAPTERS The ST fiber optic adapters include the single mode and multimode types. These ST fiber adapters are simplex style, most are with zirconia sleeves, and optional bronze sleeve adapters are available for multimode. ST fiber optic adapter features: Compact design High precision alignment Low insertion and return loss and back reflection Choice of metal or plastic housing, phosphor bronze or zirconia split sleeves ST fiber optic adapter applications: Premise installations Telecommunication networks Instrumentation 35

MT – RJ ADAPTER MT-RJ fiber adapters are with polymer housing, with flange type adapters and SC footprint types available. MTRJ fiber optic adapter features: Plug-jack (RJ-45) design TIA/EIA 568-A Compliant MTRJ fiber optic adapter applications: Gigabit Ethernet, Asynchronous Transmission Method (ATM) CATV Active Device/Transceiver Interface Premise Installations Telecommunication Networks Multimedia Industrial and Military LC ADAPTER LC adapters are single mode and multimode styles with plastic housing and zirconia sleeve, with optional bronze sleeve adapters for multimode. There are stand LC fiber adapter and SC footprint LC fiber optic adapters available. LC fiber optic adapter features: Compact design Color coding & polarization High precision alignment Low insertion and return loss and back reflection LC fiber optic adapter applications: Video CATV Active device/Transceiver interface Telecommunication networks Premise installations Multimedia Gigabit Ethernet 36

FC ADAPTERS FC fiber optic adapters, including square type, single D type and double D types, in single mode and multimode versions. All these adapters are with metal housing and ceramic sleeves. The FC square fiber optic adapter is available in the standard body styles with nickel plated brass or nickel plated zinc housing and arecorrosion resistance. FC fiber optic adapter features: Compact design High precision alignment Low insertion and return loss and back reflection* FC fiber optic adapter applications: CATV Telecommunication networks Local Area Networks (LANs) Metro networks Data processing networks E2000 ADAPTER E2000 fiber adapters are with zirconia sleeves and in simplex style. E2000 is a trademark of Diamond company. E2000 fiber optic adapter features: Secure transmission of high bit-rate protocols Compliant with European (EN 186270) and International (IEC 61754-15) standards Tested and approved by Swisscom E2000 fiber optic adapter applications: WANs, LANs, CATV Metrology, Railway, Industry 37

FSMA ADAPTER Features: High precision Easy installation Low insertion loss Good exchangeability and repeatability Zirconia and phosphor-bronze sleeve Applications: Telecommunication Computer network CATV networks Instrumentation Active device termination MPO ADAPTERS Specifications: Compact design, accommodating 4, 8 or 12 fiber ribbons High precision alignment Low insertionand return loss and back reflection. Applications: Equipment Interconnections Telecommunications networks Broadband/CATV networks Data communications networks, including high-bandwidth equipment Interconnections for parallel optical transmitters and receivers 38

FDDI ADAPTERS Features: Dual-(DAS) or Single-(SAS) Attachment Station options available Optical Bypass Switch Control Fully software configurable Applications: SAFENET applications Distributed real-time applications Vetronics applications Mission-critical applications SCADA applications 39

ATTENUATORS Fiber optic attenuator is used in the fiber optic communications to reduce the optical fiber power at a certain level, the most commonly used type is female to male plug type fiber optic attenuator, it has the optical fiber connector at one side and the other side is a female type fiber optic adapter, fiber optic attenuator name is based on the connector type and the attenuation level. SC 5dB fiber optic attenuator means this attenuator use SC fiber optic connector and it can reduce the optical fiber power level by 5dB. Commonly used attenuation range is from 1dB to 20dB. Adjustable fiber optic attenuator, also called variable fiber optic attenuator , usually is inline type, the appearance like fiber optic patch cord; it is with an adjustable component in the middle of the device to change the attenuation level to a certain figure. There are also handheld variable fiber optic attenuators; they are used as test equipment, and we have the inline fiber optic attenuators . SCATTENUATORS Features: They fit typical 1310nm and 1550nm single mode fiber applications. Attenuation range is from 1dB to 30dB. The SC fiber attenuators are with SC connector interface. They are with premium ceramic sleeves. Plug type SC fiber attenuator is a female to male type. Bulkhead SC fiber attenuator is a female to female type. Operation wavelength range is 1240nm to 1620nm. They are used inline to decrease the optical power light in the systems for both lab and commercial applications. The SC fiber optic attenuators are very good performance and fairly good price. LCATTENUATORS Features: They are with high quality ceramic sleeves and UPC polishes. Attenuation range available is from 1dB to 30dB. Working range of the LC fiber attenuator is 1240nm to 1620nm, including the typical 1310nm and 1550nm single mode applications. They are constructed of the highest quality materials and every piece is tested during production. The LC fiber optic attenuator is used with fiber amplifier, DWDM and telecommunications equipment. 40

FCATTENUATORS Features: Ceramic sleeves and accurate FC connection interface. The attenuation range is from 1dB to 30dB available. The FC fiber attenuator features high power endurance and low back reflection. Reduce the optical power in the fiber optic links. Applications include CATV networks, data communication and telecommunication networks. STATTENUATORS Features: They are with 1240nm to 1620nm compatible working wavelength, including the 1310nm and 1550nm typical single mode wavelength. Equipped with ceramic sleeves and features high quality and long lifetime. Attenuation range is from 1dB to 30dB. The ST fiber attenuators are used inline to reduce the fiber optic power by a certain fixed value. They are high attenuation accuracy and working temperature from -40 C to +75 C. E2000 ATTENUATORS Features: Low back reflection and Low PDL High precision attenuation value Precision control of attenuation range Wide attenuation range Precision ceramic ferrule Plastic or metal housing material 41

MPO ATTENUATORS Features: Durability High precision alignment Wavelength Independent Simple and Reliable Structure ROHS compliant MT – RJ ATTENUATORS Features: Low back reflection and Low PDL High precision attenuation value Precision control of attenuation range Wide attenuation range Precision ceramic ferrule Plastic or metal housing material Low price 42

FTTH 43

CUSTOMER PREMISES 44

FTTH CABLES Fiber optic "cable" refers to the complete assembly of fibers, strength members and jacket. Fiber optic cables come in lots of different types, depending on the number of fibers and how and where it will be installed. Choose cable carefully as the choice will affect how easy it is to install, splice or terminate and, most important, what it will cost! Choosing a Cable Cable's job is to protect the fibers from the hazards encountered in an installation. Will the cables be exposed to chemicals or have to withstand a wide temperature range? What about being gnawed on by a woodchuck or prairie dog? Inside buildings, cables don't have to be so strong to protect the fibers, but they have to meet all fire code provisions. Outside the building, it depends on whether the cable is buried directly, pulled in conduit, strung aerially or whatever. You should contact several cable manufacturers (two minimum, three preferred) and give them the specs. They will want to know where the cable is going, how many fibers you need and what kind (singlemode or multimode or both in what we call "hybrid" cables.) You can also have a "composite" cable that includes copper conductors for signals or power. The cable companies will evaluate your requirements and make suggestions. Then you can get competitive bids. Since the plan will call for a certain number of fibers, consider adding spare fibers to the cable - fibers are cheap! That way, you won't be in trouble if you break a fiber or two when splicing, breaking-out or terminating fibers. And request the end user consider their future expansion needs. Most users install lots more fibers than needed, especially adding singlemode fiber to multimode fiber cables for campus or backbone applications. Cable Design Criteria Pulling Strength: Some cables are simply laid into cable trays or ditches, so pull strength is not too important. But other cable may be pulled thorough 2 km or more of conduit. Even with lots of cable lubricant, pulling tension can be high. Most cables get their strength from an aramid fiber (Kevlar is the DuPont trade name), a unique polymer fiber that is very strong but does not stretch - so pulling on it will not stress the other components in the cable. The simplest simplex cable has pull strength of 100-200 pounds, while outside plant cable may have a specification of over 800 pounds. Water Protection: Outdoors, every cable must be protected from water or moisture. It starts with a moisture resistant jacket, usually PE (polyethylene), and a filling of water-blocking material. The usual way is to flood the cable with a water-blocking gel. It's effective but messy - requiring a gel remover. A newer alternative is dry water blocking using a miracle powder - the stuff developed to absorb moisture in disposable diapers. 45

Fire Code Ratings: Every cable installed indoors must meet fire codes. That means the jacket must be rated for fire resistance, with ratings for general use, riser (a vertical cable feeds flames more than horizontal) and plenum (for installation in air-handling areas. Most indoor cables us PVC (polyvinyl chloride) jacketing for fire retardance. In the United States, all premises cables must carry identification and flammability ratings per the NEC (National Electrical Code) paragraph 770. These ratings are: NEC Rating Description OFN Optical fiber non-conductive OFC Optical fiber conductive OFNG or OFCG General purpose OFNR or OFCR Riser rated cable for vertical runs OFNP or OFCP Plenum rated cables for use in air-handling plenums OFN-LS Low smoke density 46

SIMPLEX FLAT INDOOR CABLE USED UNDER CARPET Features: Good mechanical and environmental characteristics. Flame retardant characteristics meet the requirements of relevant standards. The mechanical characteristics meet the requirements of relevant standards. Soft, flexible, easy to splice. Big capacity for data transmission. Meets various requirements of market and clients. Application: Used in indoor cabling, especially used under carpet. Specifications: Fiber Cable Cable count dimension weight Mm 1 2.5 x 4.5 kg/km 15.5 Tensile Tensile (N) (N) Crush Crush Long term 80 Long term 100 Short term 500 Short term 150 Min. bend radius Dynamic Min. bend radius Static Range of temperature 50 30 -20 to +60 °C DUPLEX FLAT INDOOR CABLE I Features: Good mechanical and environmental characteristics. Flame retardant characteristics meet the requirements of relevant standards. The mechanical characteristics meet the requirements of the relevant standards. Soft, flexible, easy to splice. Big capacity for data transmission. Meet various requirements of market and clients. Applications: Used as pigtails and patch cords. Used in optical connections in optical communication rooms, optical distribution frames, optical apparatus and equipments. Used in indoor cabling. 47

Specifications: Fiber Cable Cable count dimension weight Mm 2 2 2 2 2 2 1.6 x 3.4 1.8 x 3.8 2.0 x 4.2 2.4 x 5.0 2.8 x 5.8 3.0 x 6.2 kg/km 4.0 5.0 6.0 9.0 10.4 11.0 Tensile Tensile (N) (N) Crush Crush Long term 60 80 100 100 160 160 Long term 200 200 200 200 Short term 1000 1000 1000 1000 Short term 120 160 200 200 300 300 Min. bend radius Dynamic Min. bend radius Static Range of temperature 50 50 50 50 60 60 30 30 30 30 30 30 -20 to +60 -20 to +60 -20 to +60 -20 to +60 -20 to +60 -20 to +60 °C DUPLEX FLAT INDOOR CABLE III Features: Good mechanical and environmental characteristics. Flame retardant characteristics meet the requirements of relevant standards. The mechanical characteristics meet the requirements of the relevant standards. Soft, flexible, easy to splice. Big capacity for data transmission. Meet various requirements of market and clients. Applications: Used in indoor cabling, especially in poor laying conditions. Used in optical connections in optical communication equipment rooms and optical distribution frames. Used as pigtails and patch cords. Specifications: Fiber Cable Cable count dimension weight Mm 2 2 2 2.6 x 4.8 3.0 x 5.0 4.0 x 7.0 kg/km 9.4 11.3 18.0 Tensile Tensile (N) (N) Crush Crush Long term 100 100 160 Long term 200 200 200 Short term 1500 1500 1500 Short term 200 200 300 Min. bend radius Dynamic Min. bend radius Static Range of temperature 100 100 100 35 40 40 -20 to +60 -20 to +60 -20 to +60 °C 48

DUPLEX FLAT INDOOR CABLE IV Features: Good mechanical and environmental characteristics. Flame retardant characteristics meet the requirements of relevant standards. The mechanical characteristics meet the requirements of the relevant standards. Soft, flexible, easy to splice. Big capacity for data transmission. Meet various requirements of market and clients. Applications: Used in indoor cabling, especially in poor laying conditions. Used in optical connections in optical communication equipment rooms and optical distribution frames. Used as pigtails and patch cords. Specifications: Fiber Cable Cable count dimension weight Mm 2 2 3.8 x 6.7 3.8 x 7.5 kg/km 24.0 29.0 Tensile Tensile (N) (N) Crush Crush Long term 160 160 Long term 200 200 Short term 1500 1500 Short term 300 300 Min. bend radius Dynamic Min. bend radius Static Range of temperature 100 100 40 40 -20 to +60 -20 to +60 °C DUPLEX ROUND INDOOR CABLE I Features: Good mechanical and environmental characteristics. Flame retardant characteristics meet the requirements of relevant standards. The mechanical characteristics meet the requirements of the relevant standards. Soft, flexible, easy to splice. Big capacity for data transmission. Meet various requirements of market and clients. 49

Applications: Used in indoor cabling. Used in optical connections in optical communication equipment rooms and optical distribution frames. Used in optical connections in optical apparatus and equipments. Used as pigtails and patch cords. Specifications: Fiber Cable Cable count dimension weight Mm 2 2 3.2 3.8 kg/km 8.1 10.9 Tensile Tensile (N) (N) Crush Crush Long term 100 100 Long term 200 200 Short term 1000 1000 Short term 200 200 Min. bend radius Dynamic Min. bend radius Static Range of temperature 100 100 40 40 -20 to +60 -20 to +60 °C DUPLEX ROUND INDOOR CABLE II Features: Good mechanical and environmental characteristics. Flame retardant characteristics meet the requirements of relevant standards. The mechanical characteristics meet the requirements of the relevant standards. Soft, flexible, easy to splice. Big capacity for data transmission. Meet various requirements of market and clients. Applications: Used in indoor cabling, especially in poor laying conditions. Used in optical connections in optical communication equipment rooms and optical distribution frames. Used as pigtails and patch cords. 50

Specifications: Fiber Cable Cable count dimension weight Mm 2 2 6.0 7.2 kg/km 25.3 30.0 Tensile Tensile (N) (N) Crush Crush Long term 200 250 Long term 200 200 Short term 1000 1000 Short term 400 500 Min. bend radius Dynamic Min. bend radius Static Range of temperature 20D 20D 10D 10D -20 to +60 -20 to +60 Min. bend radius Dynamic Min. bend radius Static Range of temperature 50 30 -20 to +60 °C DUPLEX FLAT INDOOR CABLE USED UNDER CARPET I Features: Good mechanical and environmental characteristics. Flame retardant characteristics meet the requirements of relevant standards. The mechanical characteristics meet the requirements of the relevant standards. Soft, flexible, easy to splice. Big capacity for data transmission. Applications: Used in indoor cabling, especially used under carpet. Specifications: Fiber Cable Cable count dimension weight Mm 2 2.2 x 16.0 kg/km 27.0 Tensile Tensile (N) (N) Crush Crush Long term 100 Long term 300 Short term 1500 Short term 200 °C 51

DUPLEX FLAT INDOOR CABLE USED UNDER CARPET II Features: Flame retardant characteristics meet the requirements of relevant standards. The mechanical characteristics meet the requirements of the relevant standards. Soft, flexible, easy to splice. Big capacity for data transmission. Applications: Used in indoor cabling, especially used under carpet. Specifications: Fiber Cable Cable count dimension weight Mm 2 2.0 x 5.0 kg/km 15.0 Tensile Tensile (N) (N) Crush Crush Long term 100 Long term 200 Short term 1000 Short term 200 Min. bend radius Dynamic Min. bend radius Static Range of temperature 50 30 -20 to +60 °C DUPLEX FLAT LOOSE TUBE INDOOR CABLE Features: Good mechanical and environmental characteristics. Flame retardant characteristics meet the requirements of relevant standards. The mechanical characteristics meet the requirements of the relevant standards. Soft, flexible, easy to splice. Big capacity for data transmission. Applications: Used in indoor cabling. Used as access building cables. Used in optical connection with higher fiber transmission requirement in optical communication equipment. 52

Specifications: Fiber Cable Cable count dimension weight Mm 2 3.8 x 6.8 kg/km 25.9 Tensile Tensile (N) (N) Crush Crush Long term 160 Long term 200 Short term 1000 Short term 300 Min. bend radius Dynamic Min. bend radius Static Range of temperature 100 40 -20 to +60 °C DUPLEX ROUND LOOSE TUBE INDOOR CABLE I Features: Good mechanical and environmental characteristics. Flame retardant characteristics meet the requirements of relevant standards. The mechanical characteristics meet the requirements of the relevant standards. Soft, flexible, easy to splice. Big capacity for data transmission. Applications: Used in indoor cabling, the cable bend radius should not be too small. Used in optical connection with higher fiber transmission requirement in optical communication equipment. Used as access building cables. Specifications: Fiber Cable Cable count dimension weight Mm 2 3.3 kg/km 10.5 Tensile Tensile (N) (N) Crush Crush Long term 100 Long term 200 Short term 1000 Short term 200 Min. bend radius Dynamic Min. bend radius Static Range of temperature 100 35 -20 to +60 °C 53

4 – FIBER PARALLEL INDOOR CABLE Features: Good mechanical and environmental characteristics. Flame retardant characteristics meet the requirements of relevant standards. The mechanical characteristics of jacket meet the requirements of relevant standards. Flexible, easy to lay and splice.

Add a comment

Related presentations

Related pages

report München: Die Sendung vom 11. Oktober | Das Erste ...

Über 70 Hilfsorganisationen erheben schwere Vorwürfe gegen die UN. report München, BR Data und das Recherchenetzwerk CORRECTIV auf den Spuren von ...
Read more

Startseite | REPORT MAINZ | SWR.de

Wie REPORT MAINZ zeigt, bieten mehrere Geschäfte in Deutschland Vollverschleierungen für Frauen und selbst Khimar-Verschleierung für Mädchen ab zwei ...
Read more

Report – Wikipedia

Report bezeichnet: Report (Journalismus), eine journalistische Darstellungsform; im betrieblichen Prozess das Vorlegen aktueller Geschäftszahlen, siehe ...
Read more

subreport ELViS

- subreport Verlag Schawe GmbH
Read more

DAT: Willkommen bei der DAT Group

Aktuell DAT-Report: Grafik des Monats Fahrzeugaufbereitung Kommentar zum Gebrauchtwagenmarkt im September 2016 Angebot und Nachfrage in gesundem ...
Read more

m+a Verlag für Messen, Ausstellungen und Kongresse GmbH

m+a report: E-Paper: Newsletter / Apps: m+a Messe News App: m+a Newsline: m+a | UFI: WIR ÜBER UNS m+a - der Fachverlag für Messen, Events und Marketing ...
Read more

REPORT MAINZ - Videos der Sendung - ARD Mediathek

Alle Videos zu REPORT MAINZ | Das Erste | Als eines der besten investigativ arbeitenden Magazine deckt REPORT MAINZ regelmäßig bundesweit Missstände in ...
Read more

Los Angeles Police Department

The Los Angeles Police Department is committed to serving the community while protecting the rights of all persons. ... FILE A POLICE REPORT ONLINE.
Read more

LaufReport - das Laufsport Journal im Internet mit ...

LaufReport – das Laufsport Journal im Internet mit Laufberichten, Reportagen, Fotos, tagesaktuellen Informationen rund ums Laufgeschehen sowie Athleten ...
Read more

News: Breaking stories & updates - News Telegraph

Latest breaking news, including politics, crime and celebrity. Find stories, updates and expert opinion.
Read more