A Clean Machine:  A Clean Machine The FEGSEM cannot operate except in a clean, ultra-high vacuum. This requires items such as: Scroll Pumps Turbo Molecular Pumps Ion Pumps as well as associated gauges and even with the cleanest of vacuums there is still The Dark Side of SEM that must be faced…. Common Vacuum Units:  Common Vacuum Units There are many varied units that are used to specify pressures The Torr, the Bar and the Pascal are in common use... .. but the Pascal is the SI recommended unit for pressure and so is the best choice for documentation 1 Atmospheric pressure is 760 mm Hg=1 Bar 1 Torr = 1 mm Hg 1 Torr = 1/760 of an atmosphere 1 milliT = 0.13Pa 1mbar = 1/1000 Atm = 0.76 Torr = 100Pa Qualitative Vacuum Ranges:  Qualitative Vacuum Ranges Low vacuum (SEC) 760 to 1 Torr Medium vacuum (SEC) 1 to 10-3 Torr High vacuum (Chamber) 10-3 to 10-6 Torr Very high (Column) 10-6 to 10-9 Torr Ultra-high (Gun) 10-9 and lower FEGSEMs contain examples of each vacuum level laminar molecular Vacuum pumps:  Vacuum pumps For each of the vacuum ranges identified earlier there is one or more type of pump that is best Pumps are always used in combination - one pump is used to start the next The sequencing of the pump down is crucial and so this is done under computer control Scroll Pumps:  Scroll Pumps Scroll pumps are the foundation of clean vacuum systems They consist of two Archimedes’ screws machined into aluminum plates mounted so that the spirals interleave One plate is held fixed while the other oscillates. Gas is trapped between the spirals and forced out to the exit port Pumping speed is constant from Atmospheric pressure down to about 1000Pa and the ultimate pressure is about 10Pa Scroll pumps are oil-free and require neither inlet nor outlet valves The world’s oldest pump technology – Archimedes’ screw Alternatively….:  Alternatively…. Roughing can also be carried out using a diaphragm pump Oscillation of the diaphragm alternately pulls gas in one port and then expels it through the other. Oil free pumps are clean but typically a factor of 3x slower, and 3x more expensive, than pumps containing oil – but worth the wait and expense Turbomolecular pump:  Turbomolecular pump Archimedian screw - runs at 20000+ rpm Needs electronic protection / control for the bearings in case of loss of power Produces a clean, oil-free, high vacuum down to 10-6 Pa Must be backed by a clean device (such as a scroll pump) Turbo pump performance:  Turbo pump performance Turbo pumps can start even at atmospheric pressure (although they labor) and they can go down to 10-8 T It is best to pre-pump the system with a clean backing system TMP do not pump all gases with same efficiency - large molecules are pumped faster than smaller molecules Turbo pump performance Ion Pumps:  Ion Pumps Ionized molecules spiral in magnetic field and get buried in Ti wall coating A large number of these structures are run in parallel to improve the pumping speed Diode pumps only handle gases that are easily ionized (no noble gases) The triode pump:  The triode pump If noble or unusual gases are expected to be found in the SEM (nitrogen, helium, counter gases from a WDS system etc.) then a triode pump must be used. The additional electrode then makes it possible to ionize these gases Ion pump performance:  Ion pump performance “The” UHV pump - goes to 10-9 Pa and below in a properly designed vacuum system Requires no backing - in fact it works best in a sealed system The IP requires a periodic bake-out into rough pumped system to clean the buried gas from the pump. This is done during the gun bake procedure Check for electrical instability by slapping the pump with an open hand. Instability indicates need for a bake Ion Pump Performance Cryogenic pump:  Cryogenic pump Cryo-pumps use liquid helium and activated charcoal absorbers to pump to 10-12 T Very high pumping speeds No vibration or magnetic fields But they need periodic bake-outs into a rough pump to clean the absorbers They are expensive to run unless used with a closed-circuit (Stirling engine) liquid He pump Vacuum Gauges:  Vacuum Gauges Vacuums systems must be monitored constantly to ensure satisfactory performance, but manufacturers seem to be reluctant to provide gauges which allow this to be done Many different types of gauges are available because each only covers a limited range of pressures Never trust a gauge unless you can check it independently Range of gauge utility Pirani gauge:  Pirani gauge The Pirani is a dedicated low vacuum gauge device The resistance of the hot wire changes with the rate of heat loss (conduction) to the gas The Wheatstone bridge then measures the change in resistance of the hot wire Pirani’s are rugged and generally reliable and rarely need attention Schematic Circuit for a Pirani (hot wire) gauge Pirani calibration:  Pirani calibration The calibration of a Pirani depends on thermal conductivity and so on the actual gas in the system Beware when using a crystal spectrometer as gases leaking from the counter tubes will degrade the accuracy of the Pirani gauge Correction Curve for Pirani Gauges Penning (Cold cathode) Gauge:  Penning (Cold cathode) Gauge A Penning gauge measures the ion current flowing from the cathode to the anode The magnetic field increases sensitivity by making the ions spiral as they travel to cause secondary ionization Beware - a Penning gauge reads zero current when the pressure is both very low and very high. The gauge must ‘strike’ to be operational Check with a Pirani gauge if in doubt Penning gauges require routine cleaning and testing Capacitance Manometer:  Capacitance Manometer Gauge head on chamber Controller and digital read-out Ion gauges:  Ion gauges Pressures lower than 10-5 Torr can be measured with ion gauges (which are miniature ion pumps) or (more usually) directly from the actual ion pump Mass spectrometer gauges (residual gas analyzers) are a desirable extra. These can measure partial pressures of e.g helium (for leak testing) or of water vapor. O-ring seals:  O-ring seals O-rings (from the 1950s) made it possible to build demountable vacuum systems The rings are now made of high tech polymers such as VITON Two kinds are in common use... Black/shiny - has filler. Low vacuum only. Lubricate with finger grease to prevent cracking Brown/dull - high vacuum, and bakeable. Do not grease Do not crush or cut the ring - ensure that it is in the groove designed for it UHV metal to metal seals:  UHV metal to metal seals First used in the 1960s Knife edges on the flanges cut into OFHC (oxygen free high conductivity) copper rings about 5mm thick to make an impermeable metal to metal seal Good down to pressures as low as 10-10 Pa Bakeable, clean, long lasting and (with care) reusable Expensive - an 8 inch gasket costs ~ $100 Don’t touch ! Vacuum Hygiene:  Vacuum Hygiene Always keep vacuum systems running 24/7/365 Use LN2 heated maze traps, and fore-line traps, to reduce backstreaming in older machines Do not overpump the sepcimen exchange chamber (SEC) as this can result in backstreaming Keep your fingers away from samples and from the specimen chamber area - wear gloves If column contamination occurs try nitrogen purging (laminar flow) over a weekend Maze trap fitted to a rotary pump Cleaning samples:  Cleaning samples Do not use organic solvents as these are always contaminated, even the fresh ‘electronic grade’ material in brown glass bottles Never, never, use squeeze or spray bottles as the TEFLON filler goes into solution Use detergents instead e.g. Alconox ‘Detergent 8’ which are bio-degradeable and leaves no residue Carbon Dioxide ‘snow’ cleaning -no residue and good solvent action but expensive to set up. CO2 “snow gun” for sample cleaning Clean is not for ever ...:  Clean is not for ever ... As soon as a specimen is prepared for observation it begins to get dirty again Even storing the sample in a vacuum dessicator will not prevent the growth of bacterial or microbial surface contaminant films because the source of the problem is carried in by the specimen itself Remedial action is required As prepared After one week Plasma cleaning:  Plasma cleaning Plasma cleaning is a rapid and easy way of removing the build-up of surface contaminants Fast and non-destructive Same sample after plasma cleaning The Dark Side of SEM:  The Dark Side of SEM The interaction of electrons with solids results in a variety of interactions which give us uniquely valuable information about the sample But these same interactions can also result in either temporary or permanent damage to the sample Know your enemy! Unwanted Beam Interactions:  Unwanted Beam Interactions Intrinsic to electron beam irradiation Unwanted beam interactions:  Unwanted beam interactions Electron beams have bad effects on organic, polymeric, and ionic materials This is ‘radiolysis’ Effect of 0.01mC/cm on protein protoxin 500nm Shrinkage of ArF resist 1mC/cm2 Radiolysis is….:  Radiolysis is…. Radiolysis is the breaking of bonds as the result of ionization by the electron. Electrons are the most intense source of ionizing radiation available - the typical dose in an SEM is equivalent to standing 6 foot from a 10 megaton H-bomb Compare SEM to Sun and SPEAR Radiolysis damage in Polymers:  Radiolysis damage in Polymers In polymers radiolysis produces swelling or shrinking in the material and the actual loss of the sample Despite appearances this damage is not due to heating in the sample The effect may be reduced by coating with metal or a thin carbon layer Courtesy Dale Newbury NIST Dose does matter:  Dose does matter A typical SEM dose for a photo-record is about 0.1 C/cm2 or 100 el/Å2 Typically at 1 -10el/Å2 we see a loss of crystallinity at 10-100 el/Å2 mass loss and above 100 el/Å2 limiting mass loss Dose from a single photo scan Is a high beam energy bad?:  Is a high beam energy bad? It is often said that low beam energies minimize or eliminates beam induced damage From casual observation this statement may appear to be true, but physics and measurements show that the truth is just the opposite And note - even a very low energy electron (1eV) has an equivalent temperature of 10,000oK, which is hotter than the surface of the sun ‘Mythbuster’ fact:  ‘Mythbuster’ fact All electrons damage At low energies the damage is high but limited by the range Damage is a maximum when range & feature sizes are similar At higher energies damage falls - energy deposition occurs outside the feature Adapted from Egerton (2004) Range<<size damage limited Range~size damage is maximum Range>>size damage limited Damage in semiconductors:  Damage in semiconductors e- beam damage of devices shifts the threshold voltage damage is localized in gate oxides and is usually reversible Damage depends on the beam energy…. and generally appears to get worse as the energy is increased Thermal damage?:  Thermal damage? Not usually a serious problem as the energy deposited is quite small For a typical material of medium density and thermal diffusivity the temperature rise with energy and beam dose is minimal Magnification 5keV 15keV 30keV 400x 0.1C/nA 0.24C/nA 0.56C/nA 4000x 0.15C/nA 0.34C/nA 0.79C/nA Other beam induced damage:  Other beam induced damage In addition to Radiolysis the beam can produce ‘knock-on’ damage In this the incident electron strikes an atom head on and knocks it out of position generating vacancies, Friedel pairs, or color centers This requires a minimum beam energy before it can occur, the value varying with the atomic number of the sample For Carbon (Z=6) the knock-on threshold energy is about 80keV, for Silicon (Z=14) the knock-on threshold is 220keV Not currently a problem with SEMs Contamination and Etching:  Contamination and Etching Contamination is beam induced polymerization of the hydrocarbons present on the sample surface Etching is the removal of surface layer by impact of ions (C + H2O 2- --> CO + H2 ) Both phenomena are affected by surface charging and often occur together Both are temperature dependent Your microscope is not to blame! Modern SEMs are very clean:  Modern SEMs are very clean RGA of S4300 chamber just before the specimen is inserted H2O N hydrocarbon but samples are not..:  but samples are not.. S4300 chamber vacuum just after sample insertion hydrocarbons from the SEC pump Contamination and Etching:  Contamination and Etching Electrons break down the hydrocarbon film by radiolysis. The residue charges +ve and the field pulls in fresh material for radiolysis. If water vapor is present then negative drift to + ve charged regions and can etch that area away Low magnification:  Low magnification At low magnifications the hydrocarbon film is polymerized into a thin sheet. This will charge positive (and so look black in the SE image) but is not a serious problem Minimize by pre-exposing the sample at the lowest possible magnification prior to examination Schematic of contamination build-up at low magnification scans Black squares...:  Black squares... The black squares are visible evidence of the charging that occurs Post facto in situ removal of contamination is possible using plasma sources in the chamber although the process is slow Use plasma cleaning before observation for best results Example shown is by courtesy of Dr. Bryan Tracy, Spansion Inc. High magnification:  High magnification At high magnification the contamination grows a cone which scatters the beam Avoid spot mode - always keep the beam scanning the sample Pre-pump samples before use Keep your hands off the sample Avoid the use of dirty solvents Plasma clean before use if possible ~ 0.03m Ant-hill contamination Virtue of necessity..:  Virtue of necessity.. Contamination cones can grow to a height of tens of nanometers and are so tough they are used for high resolution AFM tips Can prevent this growth by pre-irradiating the area at low magnification before going up to a high magnification 30nm high cones grown on a silicon wafer in spot mode - 1min Temperature effects:  Temperature effects Altering both the temperature of the sample and its surroundings will switch contamination to etching as the temperature falls This is because water vapor condenses out on the sample surface and etches the contaminant But the situation is unstable and leads to sample erosion Temperature Effects II:  Temperature Effects II Holding the sample at room temperature, but placing a cold surface close to it, can dramatically reduce the contamination rate At a low enough temperature the situation becomes stable and non-contaminating Such a device is called a “Cold Finger” It is actually a disc placed just above the sample surface operate here The Cold Finger:  The Cold Finger Standard fitting on S4700, and beyond and available as an option for the S4500 The finger is held at LN2 temperatures, a few mm from the specimen surface After allow the sample enough time to reach thermal equilibrium before starting to image Without a cold finger:  Without a cold finger This high resolution image of gold on carbon disappears in just a few seconds of observation because of the contamination build-up that occurs With a cold finger in use...:  With a cold finger in use... The equivalent area stays clean and high in contrast for an extended period of time. Remember to give the sample time enough to reach thermal equilibrium before trying to achieve high resolution Controlling contamination:  Controlling contamination “Cold fingers” are a good start Beam blanking during flyback and settling periods reduces LHS edge contamination in the S5500 Anything that reduces charging also reduces contamination and/or etching - so coating samples, pre-cleaning them, heating them prior to observation etc. all help Keep beam currents and magnifications low, use minimum dose procedures, work fast. Slide50:  50 nm The combination of a cold finger and maintaining the sample at a low temperature (-90C) eliminates contamination

Add a comment

Related presentations

Related pages

Cosmic New Year: Lecture 3 of 5 eBook by Rudolf Steiner ...

Lesen Sie Cosmic New Year: Lecture 3 of 5 von Rudolf Steiner mit Kobo. This lecture is part of the collection "Cosmic New Year" by Rudolf Steiner. Steiner ...
Read more

New Testament Lecture #3 - The Division of the NT Text ...

Western Region Pastoral Institute New Testament Lecture #3 The Division of the NT Text Mark, Matthew
Read more

Lecture 3 | New Revolutions in Particle Physics: Basic ...

Lecture 3 | New Revolutions in Particle Physics: ... In this lecture he talks about what a quantum field is and how it is related to particles.
Read more

전문 프로그래머들을 위한 프로그래밍 강좌 ...

3. 하이브리드 신규과정 ...
Read more

New Lecture 3

1 Lecture 3 Intro to PSpice III ECEL 301 ECE Laboratory I Dr. Adam Fontecchio Pre-Lab Activities zRead textbook pages 18 - 20 zRead Tutorial 4 zSkim the ...
Read more

HSAR 252 - Lecture 3 - Technology and Revolution in Roman ...

Professor Kleiner discusses the revolution in Roman architecture resulting from the ... The lecture concludes with a ... Lecture 3 - Technology and ...
Read more

Lecture III.3. Fungi. - Biology Learning Center

3 Phylogenetic Relationships. • Choanoflagellates, Fungi and Animalia form a clade. • Shared derived traits include: 1. Chitin a. Choanoflagellates ...
Read more

TOEFL® Listening: Lecture 3 : free practice test

TOEFL® Listening: Lecture 3. In this section, you will hear academic lectures. In the exam you will hear each lecture once before you look at the questions.
Read more