ICT-104 bill acceptor protocol

33 %
67 %
Information about ICT-104 bill acceptor protocol
Technology

Published on January 17, 2014

Author: imrehg

Source: slideshare.net

Description

ICT-104 communication protocol for bill acceptors

International Currency Technologies Inc. ICT Protocol For RS232 Communication Specification

ICT Protocol International Currency Technologies Corp. Change History Title ICT Protocol For Forth Published ICT, Department of Software Development Item Version Date History 1 0.1 2004.07.30 First Edition D.C 2 0.2 2011.01.24 Niki 3 0.3 2014.01.15 Remove 0x26 response Add cmd 0x5A, Escrow Hold Modify Comments ACQUA Page 2 of 7

ICT Protocol International Currency Technologies Corp. Table of Contents 1. General Information .................................................................................................................... 4 2. Communication Format............................................................................................................... 4 3. Commands................................................................................................................................... 5 3.1 Power Up........................................................................................................................... 5 3.2 Escrow............................................................................................................................... 5 3.3 Controller Polling Bill Acceptor Status ............................................................................ 6 3.4 Enable/Disable .................................................................................................................. 7 3.5 Reset .................................................................................................................................. 7 Page 3 of 7

ICT Protocol International Currency Technologies Corp. 1. General Information This specification describes the operation of ICT Interface Protocol. It is regarding to the data for the interface between Controller and ICT product. 2. Communication Format Transmission Method Full Duplex Transmission Transmission Speed 9600 Baud Rate Synchronizing Method Asynchronous Mode Connection Control Method Request Method Data Format Start bit 1 Data bit 8 Parity bit Even Stop bit 1 X parameter None Page 4 of 7

ICT Protocol International Currency Technologies Corp. 3. Commands 3.1 Power Up Bill Acceptor Controller Category Command Direction Power Supply ON 80H (128) Command Description  02H (02) Within 2 seconds 8FH (143)  1. Received 02H in 2 seconds * Bill Acceptor will be Enable status until receive 0x02 from Controller. 3.2 Escrow Bill Acceptor Controller Category Command Direction Command Description Send bill validated 81H (129)  Bill validated Send bill value 40H ~ 44H  40H : First Bill Type 41H : Second Bill Type 42H : Third Bill Type 43H : Fourth Bill Type 44H : Fifth Bill Type Wait for  02H (02) Or Request 0FH (15) (5 Seconds) Or 18H(24) Or a. Request to Accept Or b. Request to Reject Or c. *Request to Hold in Escrow d. *No response (5 seconds) Stacking (for a.) 10H (16) Controller do not need to respond Or Reject (for b)  11H (17) *Note 1: 18H will hold the bill in Escrow until receive Accept (0x02h) or Reject (0x0fh). *Note 2: If no any response after 5 mins Escrow Timeout, Bill Acceptor will Reject Bill automatically. If it continue 3 Times Escrow Timeout, Bill Acceptor Response Communication Failure. Page 5 of 7

ICT Protocol International Currency Technologies Corp. 3.3 Controller Polling Bill Acceptor Status Bill Acceptor Category Controller Command Direction Command Description 0CH (12) Request Bill Acceptor Status Controller Polling Bill Acceptor Status  Restart BA 20H (32) 21H (33) 22H (34) 23H (35) 24H (36) 25H (37) 27H (39) 28H (40) 29H (41) 2AH (42) Motor Failure Checksum Error Bill Jam Bill Remove Stacker Open Sensor Problem Bill Fish Stacker Problem Bill Reject Invalid Command . . . . 2EH(46) 2FH(47) Reserved Response when Error Status is Exclusion 3EH (62) Bill Acceptor Enable Status Bill Acceptor Inhibit Status 5EH (94) Page 6 of 7

ICT Protocol International Currency Technologies Corp. 3.4 Enable/Disable Bill Acceptor Category Controller Command Direction Command 3EH (62)  Description Controller Enable Bill Acceptor  5EH (62) Controller Disable Bill Acceptor 3.5 Reset Bill Acceptor Category Controller Command  Command Bill Acceptor Reset Power Supply ON Direction 80H (128) Command Description 30H (48)  8FH (143) 1. Received 02H in 2  02H (02) seconds * Bill Acceptor will be Enable status until receive 0x02 from Controller. No.24,Alley 38,Lane 91,Sec. 1,Nei Hu Road,Taipei,Taiwan,R.O.C. TEL : +886-2-2797-1236 FAX: +886-2-2797-1634 Web: www.ictgroup.com.tw ICT-HQ, Department of Software Development Author: ACQUA Version: V0.3 Page 7 of 7

Add a comment

Related presentations

Related pages

Bill Acceptors - Ict - Pyramid - Jcm- Validators : E&D Trading

Bill Acceptor Experts with over 30 Years Experience. Best Price Guarantee. ... © Copyright 2015 E & D Trading All rights reserved. Thermal Printers;
Read more

Home - E & D TRADING

Bill Acceptor Experts with over 30 Years Experience. Best Price Guarantee. Authorized Service ... © Copyright 2015 E & D Trading All rights reserved ...
Read more

NE77EUR4 ICT104/Pulse/PS232 B1 EEUURR44 7 DIP SWITCHES ...

NE77 DIP SWITCHES SETTING : (ICT104/Pulse/RS232 B1) SW1 OFF OFF OFF ... ICT104 Protocol Reserved ... Note1ÿ Please restart the bill acceptor after any ...
Read more

Supported bill UAH 1, 2, 5, 10, 20, 50, 100, 200, 500 9 bills.

Note3ÿ Dip 6 turn OFF (MDB Protocolÿ Accept UAH 500). ... (Bill acceptor will disable while recycler is full.) Banknote(s) dispensing mode.
Read more

Supported bill ? 20, 50, 100, 500 4bills. PulseICT MDB

... Please reset the bill acceptor after any changes on Dip switch. (2) SW7 and SW8 of the 8-switch DIP and the 4-switch DIP are for pulse protocol only ...
Read more

/LX7 Option Switch Settings: 1(Pulse/ICT104URS232 A0/ccNet ...

Note : (1) Reset the bill acceptor after setting the dip switch. (2) SW7 and SW8 of the 8-switch DIP and the 4-switch DIP are for pulse protocol only.
Read more

L L70-COP6 L70/P5 ICT104U/ccTalk DIP SWITCHES SETTING : 2 ...

Note: (1) Please reset the bill acceptor after any changes on Dip switch. (2) Dip switches 1 to 5 are only used for pulse protocol. (3) ...
Read more

prototype Archives - ClickedyClick - Gergely Imreh

... the bill acceptor. I have looked around on eBay, and Alibaba for a Taiwan Dollar (TWD) bill acceptor, ... (i.e. no protocol, no nothing), ...
Read more