Elitery The First Tier III Certified data center in South East Asia by Uptime Institute

50 %
50 %
Information about Elitery The First Tier III Certified data center in South East Asia by...
Technology

Published on April 26, 2014

Author: hendrasuryakusuma

Source: slideshare.net

Description

Indonesia technologicaly advanced Data Center, with Tier III Certification

Building and Facility Pictures

Elitery Certifications Loading Space

Elitery Data Center Lay Out Loading Space

Loading Space

Loading Space

5 • Located 200 meter above the sea level, in flood free area. • Strategically located in 42 km south of Jakarta, ideal for DRC site. • Easy access to Jagorawi Toll Road connecting to Jakarta Inner and outer ring Road. • Gas supply from PGN (government owned gas company), for chiller engine. • Electricity supplied by two different substations, from two different power plants. • Five Tier One Backbone Telco providers already have their FO network in the facility, namely; Telkom, Lintas Arta, Indosat, Icon +area and Linknet/First Media. • Police Station, Fire House and Hospital are five minutes away. • No government buildings and no factories in surrounding areas, reducing social unrest risk such as labor demo, etc. Bogor Site SITE

Front view from Pajajaran Street

Parking lot and diesel fuel tanks area

Make up water tanks area

Steel gate

Reception area and staging room, first floor

Meeting room, first floor

Building Management System, basement floor

ATS Wing C. Form 3B Power Panel, basement floor

FM 200 Fire Suppression, base ment floor

2 Perkins Genset @1.5 MW, basement floor

High end Genset Controller by Schneider, basement floor

Water pumps, basement 1 floor

Gas Substation for chiller engine basement floor

• Cool water tower (N+1) •Chiller engine (N+1) Chiller engine and cool water tower, basement floor

Electricity Substations, from two different power plants

•UPS Battery Wing A, Capacitor Banks and UPS, basement floor • UPS N+1

Lounge area, 6th floor

Engineers bedroom, 6th floor

Cooling towers and pipes, 7th floor

Our Offer: Elitery Data Center – Building Specs Gross Area: 5000m2 (50,000 ft2) Building Management System Concurrently Maintainable Building Multiple Separated M&E Rooms with redundant AHU units Dual Redundancy Chill Water Chillers System Dual Redundancy Cooling Tower System Dual Redundancy Pump System Special Design Diesel Generators Room 216.000 Liters Diesel Tanks 100,000 Liters makeup Water Tanks 100,000 Liters Hydrant Water Tanks 100,000 Liters Ground Water Tanks Structure: Reinforce Concrete Structure building with Fire resistance walls Earthquake Resistance Building up to 8.5 RS 5.0 m slab to slab height Column spacing primarily based on 7 & 8.5m grid Bomb, Bullet & Quake resistance windows Dual Separated & compartmented Risers Passenger/Cargo Lift 1x1.6 tones (2x2 meters internal dimension) Positive Air Intake Building

Our Offer: Elitery Data Center – Data Center Specs Gross Area: 1,320m2 (13,200 ft2) Gross Raise Floor: 1,140m2 (11,400 ft2) Structure: Data Center floor loading of 1 tone Reinforced Concrete Floor with Fire & Water Resistance applied Floor 5 meters slabs to slabs Height Flooring 0.8 meter high 1 ton Raised floor with anti static tiles Dual Feed Chilled water pipe on ring topology Under Raised Floor Dual Feed Zonings Power Distribution System Under Raised Floor Pre Action FM 200 Above & Under Raised Floor Smoke, Heat & water Detection system above & Under Raised Trap man Door applied Redundant Duel Coil CRAC Parameter Cooling Separated Utility from Datacenter Floor State of the art Access Door System State of the art CCTV & Surveillance System

Our Offer: Elitery Data Center – Power and Environment System Specs Power 2 Separated Power Feeds to 2 Dry Transformer Form 3B Power Panels System Bus Bar Panel Interconnection N +1 centralized redundant UPS system Battery reserve 15 to 30 minutes depends on load Individual Rack power outlet (Form 2B) 100% Full backup generating Onsite diesel tank support up to 14 days (216.000 liters) Environmental System N+1 Total Redundancies Water Cool Chiller System N+1 Total Redundancies Chilled Water Piping System N+1 Dual Coil Precision Air Conditioning System Up to 15--‐30 Minets CWT depends on Load Temperature maintained at 22oC (+/-2oC) Humidity range of 45% (+/-10%)

Thank you

Add a comment

Related presentations

Presentación que realice en el Evento Nacional de Gobierno Abierto, realizado los ...

In this presentation we will describe our experience developing with a highly dyna...

Presentation to the LITA Forum 7th November 2014 Albuquerque, NM

Un recorrido por los cambios que nos generará el wearabletech en el futuro

Um paralelo entre as novidades & mercado em Wearable Computing e Tecnologias Assis...

Microsoft finally joins the smartwatch and fitness tracker game by introducing the...

Related pages

Data Center and Colocation Service ~ Elitery Indonesia

Certified Tier III Data Center in ... Tier III Data Center Facility in South East Asia, ... of the data center in Indonesia, DCI, Elitery, ...
Read more

Elitery Data Center Services and Disaster Recovery Center

Elitery Data Center Services. Elitery is the first Tier III certified data center in South East Asia by Uptime Institute. Our state of the art facility are ...
Read more

Elitery Tier III Uptime Institute Certified Data Center ...

Elitery Tier III Uptime Institute Certified Data Center in South East Asia
Read more

Faasri Data Center - TIER IV Ready Data Center

Uptime Certified. The First and a True Tier III Data Center in South East Asia. Certified by Up Time Institute - Faasri - Elitery Data Center -
Read more

Uptime Institute - Tier Certification - All Certifications

Uptime Institute Tier Certifications ... Tier III Silver ... Data Center East. New Albany, Ohio USA. US Bancorp.
Read more

Singapore’s First Uptime Institute Tier III Data Centre ...

Singapore’s First Uptime Institute Tier III Data Centre. ... data. The ASEAN markets of South East Asia ... first Uptime Institute Tier 3 certified ...
Read more

Uptime Institute | LinkedIn

CenturyLink is First Data Center Hosting ... are Uptime Institute Certified Tier III for ... Tier III Certified data center in South East Asia ...
Read more

Hendra Suryakusuma | Facebook

Join Facebook to connect with Hendra Suryakusuma and ... The first TIER III certified data center in South East ... Classic & Sports Car, Elitery ...
Read more