ANC-100e RSLinx Ethernet IP to DH+ Classic Configuration - M2A2 (1)

75 %
25 %
Information about ANC-100e RSLinx Ethernet IP to DH+ Classic Configuration - M2A2 (1)
Science-Technology

Published on March 16, 2016

Author: arturo345918

Source: authorstream.com

slide 1: ANC-100e Ethernet to DH+ Adapter RSLinx Classic Configuration This document provides information to configure RSLinx Classic to communicate with a DH+ network from a computer using an ANC-100e Ethernet to Data Highway Plus adapter. Note: Before proceeding make sure  Network adapter is correctly configured to access ANC-100e  ANC-100e is connected to the computer or Ethernet network and DH+ network Refer to appendix for Connections instructions and more information 1. Open “RSLinx Classic” 2. Click on “Communications” menu 3. Click on “Configure Drivers” slide 2: 2 ANC-100e Ethernet to DH+ Adapter 4. Select “Remote Devices via Linx Gateway” from the Drop down list 5. Click on “Add New” Button 6. Enter the name for the driver or use the default name 7. Click “OK” 8. Enter the IP address of ANC-100e in the “Server’s IP Address or hostname:” field Default is 192.168.137.2 9. Click “OK” slide 3: 3 ANC-100e Ethernet to DH+ Adapter 10. Verify that the Driver is “Running” 11. Click on “Close” button 12. Open “RSWho” window 13. Click the checkbox to activate “Autobrowse” option 14. Double click on the driver element In our example is TCP-1 to start browsing the ANC-100e. During browsing you will notice that more elements appear in a branch fashion 15. Keep browsing until you reach “CH A Data Highway plus” All the devices connected to the same DH+ network as the ANC-100e will appear here slide 4: 4 ANC-100e Ethernet to DH+ Adapter Appendix ANC-100e DH+ connection There are 2 ways to connect to the DH+ network. - Connect to Processor’s 3-pin connector: Daisy chain a cable from the last DH+ node to the connector of ANC-100e. Polarity of blue and clear cables is irrelevant as it is auto-detected by ANC-100e - Connect to DH+ Programming Terminal on processor by using the ANC-100e Mini-Din Programming Cable Connect the DH+ cable to ANC-100e and then connect to your Ethernet network or a free Ethernet port on your computer. When the unit turns on the Ethernet LED blinks several times. Note: if AUTO Baud rate and AUTO DH+ Node options are active in ANC-100e the device will automatically configure the correct DH+ network speed and find a free DH+ node number to use as its own address. So you don’t need any configuration to start programming DH+ processor. The ANC-100e DH+ LED blinks every 3 seconds if it is associated with the DH+ network and nothing is being transmitted on the DH+ link. When DH+ data exchange takes place the LED will indicate this by blinking rapidly upon transmitting/receiving a valid DH+ packet. DH+ LED will remain off if the DH+ network is not connected or there are no devices on the connected network. About RSWho window and AutoBrowse option RSLinx “Autobrowse” option is good to initially discover all active nodes on a particular DH+ network quickly and easily however because of the extra traffic this feature generates it is recommended to have the “Autobrowse” checkbox unchecked in the production environment. For more information about settings and other options please refer to ANC-100e User Manual.

Add a comment

Related presentations

Related pages

ANC-120e RSLINX USB to DH+ User Manual-RevM3A2

ANC-100e RSLinx Ethernet IP to DH+ Classic Configuration - M2A2 (1) ANC-100e RSLinx Ethernet IP to DH+ Classic Configuration - M2A2 (1)
Read more

Micrologix Ethernet/IP configuration in Allen Bradley's RsLinx

Step by step on configuring your Ethernet/IP driver in RsLinx. ... Ethernet IP Configuration ... Configuring RSLinx Classic with the EtherNet ...
Read more

RSLinx Versions Data Server Communications | Rockwell Software

RSLinx Classic Lite can be used either as an application or service. RSLinx Classic Lite, RSLinx Classic OEM or ... EtherNet/IP Network Configuration.
Read more

Configure an Ethernet/IP Driver - Welcome to Rockwell ...

To configure an EtherNet/IP driver: ... 1. Open RSLinx software by clicking the Start menu and then choosing .
Read more

Configuring RSLinx Classic with the Ethernet device driver ...

... Allen-Bradley's RSLinx Classic to communicate ... Ethernet IP Configuration ... Configuring RSLinx Classic with the EtherNet I/P ...
Read more

RSLinx Ethernet Connection - Control.com - Forum for ...

RSLinx Ethernet Connection. ... I am using RSLinx Classic. ... The browsing feature of Ethernet/IP uses UDP/IP instead of TCP/IP.
Read more

Configuring Allen Bradley RSLinx and RSLogix for Use With ...

Configuring Allen Bradley RSLinx and RSLogix for ... Figure 1. RSLinx with RSWho Browsing Ethernet ... EtherNet/IP Driver as the driver t ype and ...
Read more

Performance and Visibility - Rockwell Automation

Performance and Visibility RSLinx ... Windows Firewall Configuration Utility 1 ... and your RSLinx Enterprise or RSLinx Classic configuration ...
Read more

Performance and Visibility - Rockwell Automation

Performance and Visibility RSLinx ... over TCP/IP networks. Programming and configuration products ... RSLinx Classic Security Configuration ...
Read more

DataLink GW1000 DF1 AB Ethernet & Ethernet/IP to DH+ & DH-485

... Bradley Data Highway Plus DH+ and RSLINX /LOGIX on Ethernet/IP. ... Classic via EThernet to DH+ Configuration is easy ... Ethernet/IP to DH ...
Read more